Minimum clearance
11.5
(7)
(6)
Fitting
8200510 BA / EN
6

Installation

The device is designed for wall or floor installation.
Select a dry place for installation.
"
Ensure a minimum clearance to the surrounding fixtures and fittings:
"
Maintain a gap of at least 5 cm on all sides (except mounted side).
F
Keep a gap of at least 80 mm at the front (projection).
F
Whilst in operation, the ambient temperature must not exceed +45 C,
F
measured 1cm away from the fans opposite side of the device.
137
5.5
(4x)
160
(174)
186
Fig. 2
Dimensional diagram for WA 121545 Booster (the numbers in brackets are for alter-
native installation
of the attachment feet)
The attachment feet are either on the side or fitted down/upwards depen-
Y
ding on variant. This gives a hole pattern of 174 mm x 137 mm (horizon-
tal alignment as in Figure 2) or 137 mm x 174 mm (vertical alignment).
Use the four screws (hole diameter 4 mm, screw diameter max. 3.5 mm)
"
to screw the Booster onto a firm, flat base at the four fitting holes provi-
ded.
Date: 21.09.2017
Operating Instructions Booster WA 121545
79
13
67.5
7