User's Manual
Ultra-Portable Smart
Blood Pressure Monitor
Model BP1, BP1A
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BP1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gima BP1

  • Page 1 User’s Manual Ultra-Portable Smart Blood Pressure Monitor Model BP1, BP1A...
  • Page 2 1. The Basics This manual contains the instructions necessary to operate the product safely and in accordance with its function and intended use. Observance of this manual is a prerequisite for proper product performance and correct operation and ensures patient and operator safety. 1.1 Safety Precision components are used in the ...
  • Page 3 must be disposed of according to the applicable local regulations. When reusing the device, confirm that the  device is clean. Do not modify the device. It may cause  accidents or damage to the device. To measure blood pressure, the arm must be ...
  • Page 4: Intended Use

    high-pressure oxygen chamber or an oxygen tent. It may cause a fire or explosion. When choosing a third party charging adaptor,  select one that complies with IEC 60950 or IEC 60601-1. Make sure the mobile APP installed in the ...
  • Page 5 2.4 Symbols Symbo Meaning Type BF-Applied Part Manufacturer European authorized representative CE Marking indicating conformance to EC directive No. 93/42/EEC CE0197 concerning medical devices. Indicate separate collection electrical and electronic equipment (WEEE). Protected against spraying water and against access to hazardous parts IP22 with a tool, per IEC 60529.
  • Page 6: Led Indications

    Follow operating instructions Serial number 3. Using the Monitor 3.1 Charge the Battery Use the USB cable to charge the monitor. Connect the USB cable to a USB charger or to the PC. A fully charge will need 2 hours. When the battery charged fully the indicator will be OFF.
  • Page 7: Applying The Arm Cuff

    3.3 Applying the Arm Cuff 1. Wrap cuff around Do not roll up shirtsleeve tightly upper arm, about 1 to 2 cm above the inside 1-2cm of the elbow, as shown. 2. Place cuff directly against Artery position skin, mark clothing cause faint...
  • Page 8 3.5 Connect the Monitor to Phone Download and install the APP Air BP from Apple Store or Google Play in your phone. Turn on the Bluetooth on the phone from setting menu. 1. Press the button on the monitor to power on, the indicator will be blue-flash that indicates Bluetooth ready-to-connect status.
  • Page 9: After Measurement

    for the next instruction. 3. In some cases, if the APP judged that the pressure in the cuff is not high enough for the measurement, then an instruction of continuous pump will be issued. Just follow the instruction. 4. The monitor will automatically deflate the cuff slowly during the measurement, a typical measurement takes about 30s.
  • Page 10: Specifications

    phone The phone Change to a doesn’t support compatible the Bluetooth phone. 4.0 BLE monitor The monitor is Reset the don’t running in an device by press response unexpected and hold the to the status. button for 5s. button press. Keep arm still measurement and don’t...
  • Page 11 MDD, 93/42/EEC EC Directive RED, 2014/53/EU ROHS 2.0, 2011/65/EU Degree protection Type BF against electrical shock Environmental Item Operating Storage Temperature 5 to 40°C -25 to 70°C Relative humidity 10% to 95% 10% to 95% (non-condensin 700 to 1060 700 to 1060 Barometric Degree of dust &...
  • Page 12 Charge input Micro USB, DC5V Rechargeable Battery type lithium-polymer battery Approximately 1000 Battery run time measurements Charge time 2 hours Blood Pressure Technology Oscillometric Method Pressure measurement 0 – 300 mmHg range Pressure ±3mmHg or±%2,whichever measurement is greater accuracy Pulse rate 40 to 200 bpm range Pulse rate...
  • Page 13: Electromagnetic Compatibility

    Max RF power -10 dBm 6. Electromagnetic Compatibility The device meets the requirements of IEC 60601-1-2. Warnings and Cautionary Advices Using accessories other than those specified  in this manual may result in increased electromagnetic emission decreased electromagnetic immunity of the equipment. The device or its components should not be ...
  • Page 14 Guidance and Declaration - Electromagnetic Emissions Blood pressure monitor intended electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Complian Electromagnetic environment Emission tests - guidance The device uses RF energy only internal function.
  • Page 15 relative humidity should be at least 30 %. ± 2 kV for Electrical ± power fast power supply transient/bur supply lines lines Mains power ± ± 1 kV for quality should be input/output input/outp that of a typical 61000-4-4 lines ut lines commercial hospital...
  • Page 16 Power frequency magnetic fields Power should frequency levels (50/60 HZ) characteristic of a 3 A/m 3 A/m magnetic typical location in field IEC typical 61000-4-8 commercial hospital environment. Note: U is the AC mains voltage prior to application of the test level. Guidance and Declaration - Electromagnetic Immunity The Blood pressure monitor is intended for use in the specified electromagnetic environment.
  • Page 17 Where, P is the maximum output power rating of the transmitter watts according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey , should be less than the compliance level...
  • Page 18 Recommended separation distances between portable and mobile RF communications equipment and the device The Blood pressure monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Blood pressure monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the monitor as recommended below, according to...
  • Page 19 Shenzhen Viatom Technology Co., Ltd. 4E, Building 3, Tingwei industrial Park, Honglang North 2 Road, Baoan, 518100 Shenzhen, P.R.China www.viatomtech.com info@viatomtech.com MedNet GmbH Borkstrasse 10 · 48163 Muenster · Germany PN:550-01222-00 Version: B June, 2018...