Testing the PAS

Test the PAS at least once a month to ensure optimal
valve performance.
Pull the T-handle with the unit completely shut down to
manually test the PAS. This action triggers an actuator,
closing the butterfly valve inside the valve body. An
audible click or series of clicks can be heard when the
actuator engages. Confirm that the valve is closed by
verifying that the reset knob is rotated completely
clockwise. If any resistance is felt, or the valve does not
close, contact Generac Mobile Products Technical
Support.

Resetting the PAS

The emergency PAS system must be reset after each
emergency event according to the steps below:
1. Turn the control power switch to OFF (O).
2. Locate the PAS valve located inside the cabinet of
the unit.
3. See
Figure
3-11. Pull T-handle on the PAS valve
outwards until there is an audible "click".
4. See
Figure
3-10. Turn rest knob counter-clockwise
90 degrees until there is an audible "click".
Owner's Manual for Flameless Heat Cart
5. Reset the T-handle.
6. Repeat steps in
start unit.