Download Print this page

Mitsubishi Electric FR-A741-5.5K Installation Manualline page 23

Hide thumbs Also See for FR-A741-5.5K:

Advertisement

Parameter
Name
Acceleration S-
380
pattern 1
Deceleration S-
381
pattern 1
Acceleration S-
382
pattern 2
Deceleration S-
383
pattern 2
Input pulse divi-
384
sion scaling fac-
tor
Frequency for
385
zero input pulse
Frequency for
386
maximum input
pulse
Orientation
*2
393
selection
Orientation
*2
396
speed gain (P
term)
Orientation
*2
speed integral
397
time
Orientation
*2
398
speed gain (D
term)
Orientation
*2
399
deceleration ratio
Position com-
*2
419
mand source
selection
Command pulse
*2
scaling factor
420
numerator
Command pulse
*2
421
scaling factor
denominator
Position loop
*2
422
gain
Position feed for-
*2
423
ward gain
Position com-
mand accelera-
*2
424
tion/deceleration
time constant
Position feed for-
*2
425
ward command
filter
*2
In-position width 0 to 32767 pulse
426
Excessive level
*2
427
error
Command pulse
*2
428
selection
Clear signal
*2
429
selection
Pulse monitor
*2
430
selection
Setting Range
Initial Value
0 to 50%
0
0 to 50%
0
0 to 50%
0
0 to 50%
0
0 to 250
0
0 to 400Hz
0
0 to 400Hz
60Hz
0, 1, 2
0
0 to 1000
60
0 to 20s
0.333s
0 to 100
1
0 to 1000
20
0, 2
0
0 to 32767
1
0 to 32767
1
−1
−1
0 to 150s
25s
0 to 100%
0
0 to 50s
0 s
0 to 5s
0 s
100
0 to 400k
40k
0 to 5
0
0, 1
0
0 to 5, 9999
9999
Parameter
Name
Second applied
450
motor
Second motor
451
control method
selection
Second motor
453
capacity
Number of sec-
454
ond motor poles
Second motor
455
excitation cur-
rent
Rated second
456
motor voltage
Rated second
457
motor frequency
Second motor
458
constant (R1)
Second motor
459
constant (R2)
Second motor
460
constant (L1)
Second motor
461
constant (L2)
Second motor
462
constant (X)
Second motor
463
auto tuning set-
ting/status
Digital position control
*2
464
sudden stop
deceleration time
*2
Lower 4 digits
465
*2
Upper 4 digits
466
*2
Lower 4 digits
467
*2
Upper 4 digits
468
*2
Lower 4 digits
469
*2
Upper 4 digits
470
*2
Lower 4 digits
471
*2
Upper 4 digits
472
*2
Lower 4 digits
473
*2
Upper 4 digits
474
*2
Lower 4 digits
475
*2
Upper 4 digits
476
*2
Lower 4 digits
477
*2
Upper 4 digits
478
PARAMETER
Setting Range
Initial Value
0 to 8, 13 to 18,
30, 33, 34, 40,
9999
43, 44, 50, 53,
54, 9999
10, 11, 12, 20,
9999
9999
0,4 to 55kW,
9999
9999
2, 4, 6, 8, 10,
9999
9999
0 to 500A, 9999
9999
0 to 1000V
400V
10 to 120Hz
60Hz
9999
0 to 50Ω, 9999
9999
9999
0 to 50Ω,
(0 to 1000mH),
9999
9999
0 to 500Ω,
(0 to 100%),
9999
9999
0, 1, 101
0
0 to 360,0s
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
17

Hide quick links:

Advertisement

loading