Instructions for the installer
For operation on 220-240V
: use an
H05RR-F / H05V2V2-F type three-core
2
cable (3 x 4 mm
).
For operation on 380-415V2N
: use an
H05RR-F / H05V2V2-F type four-core cable
2
(4 x 2.5 mm
).
For operation on 380-415V3N
: use an
H05RRF / H05V2V2-F type five-core cable
2
(5 x 1.5 mm
).
The cable end to be connected to the
appliance must be provided with an earth
wire (yellow-green) at least 20 mm longer.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above guidelines or by
interference with any part of the appliance.