To use Pressure Transducer to Calculate Subcool
• Use ▲ or ▼ button to highlight Calculate.
• Press ENTER.
• Use ▲ or ▼ button to select refrigerant.
• Press ENTER.
• Insert plug from pressure transducer into pressure transducer socket.
• Follow screen instructions to connect pressure transducer to system.
• When saturated temperature stabilizes, press ENTER.
• Press F2 (NEXT).
• Insert plug from clamp-on thermocouple into type K thermocouple socket.
• Follow screen instructions to place clamp-on thermocouple.
• When temperature has stabilized, press ENTER.
• Press F2 (NEXT).
• Actual Subcool will be displayed.
SAVING TEST INFORMATION (NEW ENTRY)
• Use NEW ENTRY to save testing information under Customer, Technician, and
Date.
To enter a New Customer
• Use power button to turn on A/C Analyzer.
• Use ▲ or ▼ buttons to highlight NEW ENTRY.
• Press ENTER.
• New Customer will be highlighted.
• Press ENTER.
• Use ▲ or ▼ buttons to adjust letter or number.
NOTE: Using ▼ button will go directly to numbers.
• Use ► or ◄ buttons to highlight next space.
• When done press ENTER.
• Use ▲, ▼, ►, or ◄ buttons to enter Technician.
• When done press ENTER.
• Press F1 (DONE).
• NEW TEST will be highlighted.
• Press ENTER.
• Any testing will be recorded under the current date. For instructions on how to do
the testing see Quick Start.
• To see the testing summary press F2 (DATA) at the end of each test except DB/
WB/RH/DP/Air Vel.
To add a test to an Existing Customer
• Use POWER button to turn on A/C Analyzer.
• Use ▲ or ▼ buttons to highlight NEW ENTRY.
• Use ▼ or ▲ buttons to highlight existing Customer.
• Press ENTER.
• NEW TEST will be highlighted.
• Press ENTER.
• Any testing will be recorded under the current date and time. For instructions on
how to do the testing see Quick Start.
• To see the testing summary press F2 (DATA) at the end of each test except DB/
WB/RH/DP/Air Vel.
LOOKING AT PREVIOUSLY SAVED INFORMATION
• Use POWER button to turn on A/C Analyzer.
• Use ▲ or ▼ buttons to highlight Customer Search.
• Press ENTER.
• Use ▲ or ▼ buttons to highlight Customer.
• Press ENTER.
• Use ▲ or ▼ buttons to highlight Test Number.
• Press ENTER.
• Saved test data will be displayed.
NOTE: The Customer or Test can be deleted by pressing F2 (DEL) when they are
highlighted.
CALIBRATION
• Use POWER button to turn on A/C Analyzer.
• From MAIN MENU press CAL button.
5