OPERATING MANUAL
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
1

Advertisement

loading

Summary of Contents for MasterCool 52251

  • Page 1 OPERATING MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
  • Page 2 English A/C SYSTEM ANALYZER MANUAL A/C SYSTEM A/C SYSTEM ANALYZER ANALYZER Type K Round Vane Thermocouple Meter Pressure Transducer Assembly with Cable Antenna Fan Meter DESCRIPTION Round Vane Meter/Antenna Insert round vane meter or antenna fan Fan Meter Socket meter into socket to use Pressure Transducer Socket Insert pressure transducer cable into socket to use...
  • Page 3: Quick Start

    • Use POWER button to turn on A/C Analyzer. • Use ▼ or ▲ buttons to highlight the date. • Press ENTER. • Use the ◄ or ► buttons to highlight the Day, Month, Year and Format. • Use the ▲ or ▼ buttons to change the values. NOTE: The format can be MM/DD/YYYY or DD/MM/YYYY.
  • Page 4 • Follow Temp Split 1 screen instructions on where to place round vane meter or antenna fan meter. • When values have stabilized, press ENTER to save. • Press F2 (NEXT). • Follow Temp Split 2 screen instructions on where to place round vane meter or antenna fan meter.
  • Page 5 To use Pressure Transducer to Calculate Subcool • Use ▲ or ▼ button to highlight Calculate. • Press ENTER. • Use ▲ or ▼ button to select refrigerant. • Press ENTER. • Insert plug from pressure transducer into pressure transducer socket. •...
  • Page 6: Specifications

    For Thermocouple Calibration NOTE: Press F4 (EXIT) in Thermocouple Cal 1 Screen to return to MAIN MENU without saving, or F2 (PT) to calibrate the pressure transducer. • Insert thermocouple into thermocouple socket. • Place thermocouple at known temperature and allow temperature to stabilize. NOTE: Use crushed ice and just enough water to cover and calibrate to 32˚F or 0˚C, or place thermocouple clamp on a heavy wall copper pipe and clamp a calibrated meter next to it.
  • Page 7 • 0.5 to 25 m/s • 0.1 m/s • ±(2% of reading +0.3 m/s) Pressure Transducer • Operating Pressure Range: 0-750 psi (0-52 bar) • 1/4FL Swivel nut connection • Accuracy: ±0.5, ±1% F.S. • Operating Temperature: -40 to 100˚C (-40 to 212˚F) Clamp-on Thermocouple Temp.
  • Page 8 Test Equipment Depot - 800.517.8431 99 Washington Street, Melrose, MA 02176 TestEquipmentDepot.com 52251-INT-INST...