2
FIELD POSITIONING
The detection field and reference position are very important for proper functioning of the barrier.
1
Activate the visible laser beams by remote control
to position the sensor correctly.
2
Use a sheet of white paper to verify that the laser beam
is positioned at 0°.
The reference point can be adjusted on any object at the
end of the barrier or farther away. Its surface should be
at least 6 inches wide and it must be secured.
Use the reflective sticker when the distance between
sensor and reference is higher than 16 feet (see page 4).
3
- The 0° spot must be parallel to the barrier.
- The beginning of the opening field should be
approximately 15 inches above the ground.
4
To finish, lock the sensor position.
75.5984.01 LZR-H100 20181221
75.5984.01 LZR-H100 20181221
0°
0°
45°
90°
To turn off the beams, use the same
sequence. After 15 minutes, the beams
turn off automatically.
Turn the sensor slightly on its axis to
adjust the lateral angle of the sensor to
place the 0° laser spot on the reference.
Adjust the tilt angle of the detection
field with the hex key if necessary.
0°
0°
Page 9 of 16