SAFETY
CAUTION!
Use of controls, adjustments or performance of procedures other than those specified herein may result
in hazardous radiation exposure.
Do not look into the laser
emitter or the visible red
laser beams.
This sensor is designed to be used as a movement and presence sensor to control the opening and the closing process
of a gate or a barrier. The installer of the system is responsible for installing the sensor and the system in compliance
with applicable national and international standards on safety. The manufacturer of the sensor cannot be held
responsible for incorrect installations or inappropriate adjustments of the sensor.
This device is not intended for use in with any automatically activated doors. US Pat. No. 7,084,388, which is not
owned by BEA, covers automatic doors comprising, among other things, a scanning detector. The LZR-H100 is not
sold with consent, implied or otherwise, for use with automatically activated doors, as set forth in the aforementioned
patent.
INSTALLATION & MAINTENANCE
Avoid extreme vibrations.
Avoid exposure to
sudden and extreme
temperature changes.
Page 2 of 6
Page 2 of 6
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Do not cover the laser
windows.
Avoid direct exposure to
high pressure cleaning.
The device contains IR and visible laser diodes.
IR laser: wavelength 905nm; max. output pulse power 75W
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 650nm; max. output CW power 3mW
(Class 3R according to IEC 60825-1)
The visible laser beams are inactive during normal functioning.
The installer can activate the visible lasers if needed.
Only trained and qualified
personnel may install and
adjust the sensor.
Avoid moving objects
and light sources in front
of the laser window.
Do not use aggressive
products to clean the
laser windows.
After installation, enter
an access code by remote
control.
Avoid the presence of
Avoid condensation on
smoke and fog in the
the laser windows.
detection field.
Clean the laser window
with compressed air. If
needed, wipe only with
a soft, clean and damp
microfibre cloth.
75.5984.01 LZR-H100 20181221
75.5984.01 LZR-H100 20181221
Keep the sensor
permanently powered in
environments where the
temperature can drop
below 35 °F.