RECOMMENDED MOUNTING

Install the sensor at a mounting height between
14 – 17 inches. If the barrier is only used by
trucks, the mouting height may be increased.
Ensure that the detection field is parallel to the
barrier.
When using the safety, place the sensor just
behind the barrier to ensure that the safety field
protects the area around the barrier.
d (in)
2
4
6
Ensure there are no obstructions in front of the
sensor!
75.5984.01 LZR-H100 20181221
75.5984.01 LZR-H100 20181221
14 – 17 in
L
(in) h
(in)
min
min
9.5
2
14
2.3
19
2.5
If the reference beam is too low or too high,
contact with the barrier may occur.
Do not position the detection field as shown.
B
A
When using the safety, do not place the sensor
before the barrier (A) or more than 15 inches after
the barrier (B). The area around the barrier is not safe.
Do not cover the front face of the sensor with
glass or plastic.