Technical Specifications - BEA LZR-H100 User Manual

Laser scanner for barriers & gates
Hide thumbs Also See for LZR-H100:
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS

Technology
Detection mode
Max. detection field
Remission factor
Angular resolution
Emission characteristics
IR laser:
Red visible laser:
Supply voltage
Power consumption
Peak current at power-on:
Cable length:
Response time
Motion detection:
Presence detection:
Output:
Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:
Test input:
Max. contact voltage:
Voltage threshold:
LED-signal:
Dimensions:
Material / Colour:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screens:
Norm conformity:
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.BEAinc.com
Page 16 of 16
Page 16 of 16
LASER scanner, time-of-flight measurement (4 laser curtains)
motion and presence
32' × 32'
>2%
0.3516°
wavelength 905 nm; max. output pulse power 75 W (CLASS 1)
wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)
10 – 35 VDC @ sensor side
<5 W
1.8 A (max. 80 ms @ 35 V)
33'
typ. 200 ms (adjustable)
typ. 20 ms (max. 80 ms)
2 electronic relays (galvanic isolated – polarity free)
35 VDC / 24 VAC
80 mA (resistive)
t
=5 ms; t
=5 ms
ON
OFF
typ 30 Ω
<0.7 V @ 20 mA
<10 µA
1 optocoupler (galvanic isolated - polarity free)
30 VDC (over-voltage protected)
Log. H: >8 VDC
Log. L: <3 VDC
1 blue LED: power-on status
1 orange LED: error status
2 bi-colored LEDs: detection/output status (green = no detection, red = detection)
3
"× 2
"× 5"(W × H × D)
5
3
8
4
PC/ASA, black
-45°, 0°, 45°
-5 – 5° (lockable)
-3 – 3°
IP65
powered: -22 – 140 °F
0 – 95% non-condensing
<2 G
max. 30%; homogenous
IEC 61000-6-2; IEC 61000-6-3; IEC 60950-1; IEC 60825-1
ISO 13849-1 (Pl "d" CAT 2); IEC 62061 (SIL 2); IEC 61496-1 (Type 2)
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
mounting bracket: +
unpowered: 14 – 140 °F
Specifications are subject to change without prior notice.
All values measured in specific conditions.
"
1
2
75.5984.01 LZR-H100 20181221