Mounting And Wiring - BEA LZR-H100 User Manual

Laser scanner for barriers & gates
Hide thumbs Also See for LZR-H100:
Table of Contents

Advertisement

1
MOUNTING & WIRING
Carefully read the application requirements and tips before mounting the sensor.
Mounting position of the sensor is crucial for proper functioning of the barrier.
1
Use a mounting post or a mounting
accessory (e.g. LBA accessory) to
secure the sensor to the pole.
4
Firmly close the protection cover.
RED
BLACK
WHITE
GREEN
WHITE/BLACK
GREEN/WHITE
BLUE
BLUE/WHITE
ORANGE
ORANGE/BLACK
Page 8 of 16
Page 8 of 16
2
Position the bracket and secure
using the 4 screws to avoid
vibrations.
5
Position the housing on the
bracket.
POWER SUPPLY +
POWER SUPPLY -
RELAY 1 - OPENING FIELD
RELAY 2 - SAFETY FIELD
TEST +
TEST -
NOT USED
LED signal at power-on:
Correct positioning is needed
Power on without test signal:
Connect blue/white and blue
wires to test or power supply.
3
Open the protection cover, plug
the connector and position the
cable in the slit.
6
IN
Turn the sensor until the two
triangles are aligned.
No test function:
Connect BLUE (DC+) and BLUE/WHITE
(DC-) to power supply.
(no polarity)
No detection
Safety and opening detection
75.5984.01 LZR-H100 20181221
75.5984.01 LZR-H100 20181221
LOCK