Toshiba RAV-GM1101AT8P-E Service Manual page 57

Outdoor unit digital r32 inverter
Hide thumbs Also See for RAV-GM1101AT8P-E:
Table of Contents

Advertisement

Check
Outdoor
code
LED display
[P04]
Check and troubleshooting
(Item without special mention Indicates part of outdoor unit.)
[High pressure SW system error]
Does high pressure switch
operate?
YES
Are parts of
high pressure switch correct?
YES
Is service valve fully opened?
YES
Reset the power supply and
then make a test run.
Does outdoor fan correctly operate?
YES
Is there any element
which blocks heat exchanger
of the outdoor unit?
Clogging of heat exchanger
Short circuit
NO
- 57 -
FILE NO.SVM-18044-1
NO
Is circuit wiring correct?
NO
Parts check
Defective → Replace
NO
Open service valve fully.
Check outdoor PC board
Defective → Replace
NO
Is there fan breakage
or coming-off?
NO
Repair defective position.
Connection of connectors,
outdoor P.C. board,
Fan motor, Wiring.
YES
blocking element
Overcharge of refrigerant/
Clogging/Pipe breakage/
Abnormal overload
NO
Wiring check,
Correct.
YES
YES
Elimination of

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents