Symbol definition: Symbolizes an important information Symbolizes additional information Symbolizes necessary actions during installation and start up Terminology: The following technical terms are used in these instructions: Permeate: Demineralised water produced by the RO-unit which is fed into the integrated storage tank Concentrate: Water containing the salts and minerals extracted from the raw water.
Page 3
Location of the RO-unit: The RO-unit must be installed in a location with open floor drain Install the RO-unit in a frost-free location. Install the RO-unit on an even horizontal surface, otherwise the storage tank of the RO-unit may overflow. The surface must be capable of withstanding a weight of approx.
Page 4
Plumbing: The water connections for the RO-unit must meet the requirements of all present regulations The RO-unit must be connected to the cold water supply (max 25 Install a water shut-off valve and a water meter in the raw water inlet. Maximum hardness of inlet water 25 dh .( compact 1) dh .( compact 2 &...
Water quality: The raw water, which will be treated in the RO-unit, must be of drinking water quality and must not contain more than up to 1000 mg/l TDS as CACO In addition to this the raw water must not exceed these limit values for chemi- cal substances: 0,05 mg/l 0,02 mg/l...
Page 6
Wiring: The electrical connection must be done in accordance with all local rules and regulations. 230 V – 50 Hz Voltage: Fuse: 10/16 Ampere Electricity consumption: 1,1 kWh compact1 & 2, 1,7kWh Compact 3 Colour-codes for connection cable wires: Conductor, blue: Conductor, brown: Live...
Page 7
Connecting the RO-unit: Connect the feed water with a ¾” flexible water connection tube to the micro filter and the water inlet of the RO-unit (connection point 1). Mount a ¾” flexible water connection tube to the outlet connection point of the RO- unit (connection point 2) and connect the other end to the user application.
Page 8
Start-up the RO-Unit: Before start-up check that all plumbing and wiring has been done in accordance with all local rules and regulations. Open the water shot-off valve. Check that all water connections are tight. Insert the main plug ...
Page 9
As soon as approx. 9 – 11 litres of permeate have been removed, the high-pressure pump switches on to start permeate production. The time taken depends on the tem- perature of the raw water, but should average around 3 to 4 minutes. ...
Technical data Model: RO-Compact1 RO-Compact2 RO-Compact3 Dimensions 560 x 250 x 760 580 x 460 x 700 580 x 460 x 700 DxWxH/mm Production Rate 15°c 800µs, (lph) Minimum Inlet Flow 6,67 l/m 40% 10 l/m 50% 14 l/m 50% Rate L/minute Membrane Type Thin Film Low 3...
Page 13
Feed water Permeate (connect to user application) Concentrate drain Over flow connection from storage tank Electrical hook up The enclosed ¾” Inlet screen must be installed between the inlet hose and the inlet of the RO-unit to protect the Ro-unit from dirt. This micro filter must be removed and cleaned every 6 month at a minimum, or if the plumbing of the building is being repaired.
TEST REPORT DATE: TYPE OF UNIT: SERIAL NO.: TEST STATION: DENSITY: INLET PRESSURE: C INLET TEMP.: PRESSURE SWITCH ENDS: CONCENTRATE: HIGH PRESSURE PUMP: LEVEL SWITCH: HIGH: MEDIUM: LOW: PERMEATE: S CONDUCTIVITY: FEED WATER PUMP: FEED WATER PUMP: PRODUCTION TIME: LTR.: SEC.: NOZZLE NO.