Water quality:

The raw water, which will be treated in the RO-unit, must be of drinking water
quality and must not contain more than up to 1000 mg/l TDS as CACO
In addition to this the raw water must not exceed these limit values for chemi-
cal substances:
!
Fe:
Mg:
Chlorine, free:
NTU, max:
Silt index SDI: < 3,0
Temp. Max:
KmnO4, max:
Water pressure: 2 – 7 bar
In case of doubts about the chemical substances of the raw water a water
analysis must be performed.
The raw water is of drinking water quality
The feed water to the RO-unit does not exceed the limit values above.
0,05 mg/l
0,02 mg/l
0,1 mg/l
1,0
o
25
C
10,0 mg/l
.
3
5