Inputs. . . Continued

encoder toggle Function

The Input Encoder can be programmed to toggle any one of the input
functions with a single push (ie., without having to enter the Config
Menu screen). This can be very useful when, for example, experimenting with
microphone phasing.
To select a function for the Input Encoder toggle feature:
Enter the Config Menu screen
1
Scroll to the function required for the toggle feature
2
Press-and-hold the Input Encoder until the confirmation
3
message appears in the input display
The selected function will now toggle on/off each time the Input
Encoder is clicked*. If 'Type' (default) is selected, clicking the Input
Encoder will step through the available inputs.
*Selecting a function that is not available for the current input type will have no
effect, but the function will be stored and become active when an appropriate
input type is selected.

Line Inputs

Although analogue inputs [1-4/1-8/1-2] can be switched between
the Mic, Line and Instrument connectors, the remaining Line inputs
[5-8/9-16/3-16] are always available on the DB25 connector(s) on
the rear panel.

operating Level selection

(Red 16Line only)
The operating level for each Line input can be switched between +18
dBu and +24 dBu to correctly match additional studio equipment.
To set the level:
Press and hold the Input button until the Level Selection menu
1
appears on the Input Display
Scroll to the required channel number for individual selection
2
or to all for global selection
Click the Input Encoder to toggle between +18 dBu and +24 dBu
3
Press the Input button again to exit
4
Input and output operating level selection can be linked or unlinked. Refer to:
Global Settings – I/O Level on page 22 for additional information.
13
Type
Mic
+24dBu
+18dBu
Level
On
Off
+48V
Phase
On
Off
HPF
On
Off
Air
On
Off
Link
On
Off
Input Encoder Toggle Confirmation