SERVICING
4. CLEANING THE CONDENSATE
TRAP
This procedure must be carried out after the
appliance has been switched off and made
safe. Remove the trap by undoing nuts 'A' and
'B' . Clean the trap by removing plug 'C' taking
precautions regarding water in the trap. Refit in
Flame Sensing Electrode
Flame Ignition Electrode
reverse order and check for leaks.
POWERFLUSHING/CLEANING
OF
THE
HEATING SYSTEM
If it is proposed to 'powerflush' the heating
Burner
system we would recommend that the
GulfStream appliance is isolated from the
heating system being cleaned. Failure to do this
could seriously damage the appliance.
When carrying out the work always comply
fully with the manufacturers instructions for the
powerflushing equipment being used.
If in any doubt please consult our Technical
Helpline.
4.5 ± 0.5mm
Figure 32
A
Condensate Trap
B
C
Figure 33
Page 39