Dc Link Power P; Dc,Mot Of Motoring Axis; Dc,Gen Of Regenerating Axis - ABB ACS850 Application Manual

Common dc configuration
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

Drive
Drive
A
B
M
M

DC link power P

of motoring axis
dc,mot
is the power supplied to the DC terminals to get the required mechanical
P
dc,mot
motoring power on the motor shaft. P
also covers the losses in the drive and motor.
Drive losses
Motor losses
P
m
: DC link power
P
dc
: efficiency factor (1/eff) to include drive and motor losses. If not known, value
k
eff
1.25 can be used.
: motor mechanical shaft power
P
m
: torque (Nm) on motor shaft
T
: motor shaft speed (rpm)
n
DC link power P
of regenerating axis
dc,gen
is now the power supplied from the regenerating motor to the DC terminals.
P
dc,gen
is lower than the shaft power, because the shaft power now covers also the
P
dc,gen
losses in the drive and motor.
Drive losses
Motor losses
P
dc,gen
Based on the system power profile, the following system level DC link power values
are defined.
Drive
C
M
dc,mot
=
P
k
dc
,
mot
P
dc,mot
P
(
kW
)
m
P
dc
,
gen
P
m
is higher than the shaft power, because it
×
P
eff
m
×
T
n
9550
P
=
×
m
k
eff
Common DC configurations