Installation; Power Requirements - Datalogic XRF410N Series Application Note

Table of Contents

Advertisement

INSTALLATION

GENERAL ID-NET CONFIGURATION
When using a single XRF410N-xx0 MASTER, no ID-NET network configuration is
necessary. This product leaves the factory pre-configured and the readers have
respective Master and Slave 1 roles.
When using one or more XRF410N-xx1 EXTENSION(s) with the XRF410N-xx0
MASTER, the first step is to configure the ID-NET network because the EXTENSION
Slave readers leave the factory with the unusable Slave 0 role (jolly).
The installation procedure for multi XRF readers is summarized below:
1. Mount the various XRF410Ns to the station frame.
2. Connect the ID-NET cabling, moving the ID-NET terminator to the last node in the
network.
3. Run DL.CODE™ and connect to the Master reader.
4. Run "New Configuration - Multi Device. This will assign ID-NET addresses to all the
Slaves in the network associating them with their respective serial numbers. Click
Apply Changes.
CAUTION: XRF410N models have a default baudrate of 1 Mbs and are
designed to be used in applications where the overall cable length does not
exceed 30 meters. XRF410N models can only be connected in an ID-NET
network to other XRF410N models; mixed networks with other types of Matrix
readers are not allowed.

POWER REQUIREMENTS

Depending on the number of XRF410Ns used a different power supply will be required. The
following table indicates which power supply to use for your application.
XRF410N Model
Base (Bxx)
Hi Perf (Hxx)
6
1
PG-120-K0x
PG-120-K0x
PG-120-K0x
PWR-480B
Number of Modules
2
3 to 4
PWR-480B
PWR-480B
XRF410N™ INSTALLATION
5 to 8
PWR-480B
PWR-480B (x2)

Hide quick links: