5.4
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for ULPG, perform the same operations described in
paragraph "5.3 Adjustment for ULPG", but refer to the following table
for the proper injectors.
Burner
Auxiliary
Semi-rapid
Rapid
Rapid large
Fish pan
Wok
Instructions for the installer
Adjustment for natural gas
NG – 1.0 kPa
Nominal gas
Consumption
(MJ/h)
4.8
5.9
8.6
11.4
11.4
15
Injector
(mm)
0.98
1.10
1.25
1.50
1.50
1.70
15