Instructions for the installer
5.2
1.
2.
3.
5.3
Check that the connection has been made as described in the "Gas
connection" section.
Undo the screw "D" and push the air regulator "C" fully down. Use a
spanner to remove the nozzles "B" and fit those of suitable type
following the instructions given in the tables for bottled gas ULPG 2.75
kPa. The nozzle must not be tightened to a torque of over 3 Nm.
Burner
Auxiliary
Semi-rapid
Rapid
Rapid large
Fish pan
Wok
14
Removing the hob (models with built-in control
panel)
Remove the knobs, the griddles, the burner caps, the flame caps
and the two rear plugs;
Remove the screws "A" which fix the burner supports;
Raise the hob, sliding it off the ignition plugs and/or the
thermocouples and the gas tap rods;
Adjustment for ULPG
ULPG – 2.75 kPa
Nominal gas
Consumption
(MJ/h)
4.8
5.9
8.6
9.5
9.5
15.0
Injector
(mm)
0.60
0.65
0.77
0.85
0.85
1.05