Honeywell DirectLine DL422 User Manual

Sensor module for meredian ii orp electrodes

Advertisement

Quick Links

DirectLine® DL422 Sensor Module
®
for Meredian
II ORP Electrodes
User Manual
70-82-25-107
Rev. 2
1/03
Industrial Measurement and Control

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell DirectLine DL422

  • Page 1 DirectLine® DL422 Sensor Module ® for Meredian II ORP Electrodes User Manual 70-82-25-107 Rev. 2 1/03 Industrial Measurement and Control...
  • Page 2 Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
  • Page 3 DirectLine® Sensor. Insert 70-82-10-02, a quick reference guide for configuring and calibrating the DL422, should accompany this document. Contacts World Wide Web The following lists Honeywell’s World Wide Web sites that will be of interest to our customers. Honeywell Organization WWW Address (URL) Corporate http://www.honeywell.com...
  • Page 4: Table Of Contents

    Contents 1. INTRODUCTION ........................1 Overview............................1 Electronics Module ......................... 2 Operator Interface........................... 2 Specifications..........................3 Model Selection Guide ........................4 2. INSTALLATION ........................5 Assembly and Wiring ........................5 Integral Mounting ..........................7 Remote Mounting ........................... 8 Conduit connections ........................10 3.
  • Page 5 Tables Table 2-1 Assembly and Wiring Procedure for Field Wiring Connector___________________________ 6 Table 2-2 Integral Mounting Procedure for ORP Electrodes __________________________________ 7 Table 2-3 Remote Mounting Procedure for ORP Electrodes__________________________________ 8 Table 3-1 Configuration Set Up Procedure ______________________________________________ 12 Table 4-1 Oxidation-Reduction Potential of Reference Solutions at Specified Temperature_________ 15 Table 4-2 Zero (Standardization) Calibration Procedure ____________________________________ 16 Table 5-1 Online Parameter Descriptions _______________________________________________ 17 Table 5-2 Display Navigation Procedure ________________________________________________ 17...
  • Page 6 Figures Figure 1-1 DirectLine® Sensor ________________________________________________________ 1 Figure 1-2 Electronics Module _________________________________________________________ 2 Figure 2-1 Cordset Connection and Wiring ________________________________________________ 5 Figure 2-2 Field Wiring Connector ______________________________________________________ 6 Figure 2-3 Integral Mounting __________________________________________________________ 7 Figure 2-4 Remote Mounting __________________________________________________________ 9 Figure 2-5 Remote Mounting Hardware_________________________________________________ 10 DirectLine®...
  • Page 7: Introduction

    Introduction 1. Introduction 1.1 Overview The DirectLine® Sensor consists of an electronics module connected to a Meredian II ORP electrode that eliminates the need for pre-amps, transmitters, and analyzers in ORP applications. The modular electronics design can be separated from the electrode, allowing the electrode to be easily removed or replaced while retaining power to the electronics module.
  • Page 8: Electronics Module

    Introduction 1.2 Electronics Module The electronics module is loop-powered by 16-42 Vdc and will modulate its supply current from 4 mA to 20 mA, depending upon the ORP value that is measured by the Meridian II electrode. A 4-20 mA output connection is provided via a 6m cordset or a customer supplied cable used in combination with a field wiring connector.
  • Page 9: Specifications

    Introduction 1.4 Specifications Displayed ORP –1600 mV to +1600 mV Meredian Sensor Survivable Temperature –10 °C to +130 °C (14 °F to 266 °F) Range –20 °C to +85 °C (–4 °F to +185 °F) Electronics Module Ambient Temperature Output Type 4-20 mA (2-wire loop powered) Output Scale –1600 mV to +1600 mV...
  • Page 10: Model Selection Guide

    Introduction 1.5 Model Selection Guide Instructions Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Tables I through IV using the column below the proper arrow. A dot ( ) denotes availability. Key Number _ _ _ _ _ _ _ _ _...
  • Page 11: Installation

    Installation 2. Installation 2.1 Assembly and Wiring Depending on the customer selected output cable options, the DirectLine can be wired to an appropriate 16-42 Vdc source using 2 different methods: 1) Cordset. See Figure 2-1. 2) Field wiring connector with customer supplied cable. See page 6. 2.1.1 Cordset Power Supply Minimum: 16 V @ 250 ohms (max.)
  • Page 12: Table 2-1 Assembly And Wiring Procedure For Field Wiring Connector

    Installation 2.1.2 Field Wiring Connector with customer supplied cable Refer to Figure 2-2. The field wiring connector supports customer supplied cable with an outer diameter of 4-6mm, 2-wire twisted shielded pair. Table 2-1 Assembly and Wiring Procedure for Field Wiring Connector Step Procedure Disassemble field wiring connector...
  • Page 13: Integral Mounting

    Installation 2.2 Integral Mounting Table 2-2 Integral Mounting Procedure for ORP Electrodes Step Procedure Connect Electrode to Pipe and Electronics Assembly (Figure 2-3) Screw the electrode into the pipe tee (3/4 “ NPT thread). Make sure that the final position of the installed electronics module allows the display to be easily viewed by plant personnel.
  • Page 14: Remote Mounting

    Connect cable leads as follows: Terminal 1 = Black Reference Lead Terminal 2 = 100K ohm resistor (pre-installed by Honeywell) Terminal 3 = 100K ohm resistor (pre-installed by Honeywell) Terminal 4 = Shield Terminal 5 = 1 Megohm resistor (pre-installed by Honeywell)
  • Page 15: Figure 2-4 Remote Mounting

    Installation Black Reference Lead Electronics 100K-ohm resistor (pre-installed by Honeywell) Module 100K-ohm resistor (pre-installed by Honeywell) Shield Lead 1 Megohm resistor (pre-installed by Honeywell) Red Measuring Lead and 1 Megohm resistor (pre-installed by Honeywell) Protective yellow vinyl sleeve (remove) Cover...
  • Page 16: Conduit Connections

    Installation Hose Clamp Slot for Pipe Mounting (Hose Clamp included in kit) Through Hole for DIN Rail Mounting Metal clip for Gray clip for “U” DIN rail mounting “G” DIN rail mounting Mounting Kit View from End View from End Panel Panel Panel...
  • Page 17: Configuration

    Configuration 3. Configuration 3.1 Overview Configuration Parameters Set Up consists of configuring the following functions: • Noise Suppression Frequency Selection – Selection of 50 Hz or 60 Hz. Defaults to 60 Hz at unit reset. • Output Configuration – The following Output Configuration functions can be selected: 0 % Range 0 % Range values can be adjusted within a range of...
  • Page 18: Configuration Set Up Procedure

    Configuration 3.2 Configuration Set Up Procedure ATTENTION: In Table 3-1, under the Press column: • Hold means to hold the button down until the display changes. • Momentarily means to press and release the indicated button. From the Online ORP display, follow this procedure. ATTENTION: If no key is pressed for 60 seconds, the display will abort the entry mode and default to Online Display.
  • Page 19 Configuration Step Operation Press Display 100 % Range Value rnGH (for 1 second) then, Selection (value of current 100 % Range Value Selection) Momentarily Edit 100 % Range Value MODE Flashing Display – You are now in EDIT mode Selection Hold (value of current 100 % selection) Select 100 % ORP...
  • Page 20: Calibration

    Calibration 4. Calibration 4.1 Calibration Diagnostics Introduction The manual standardization adjustment changes the zero offset diagnostics used by this system. This value is viewed as read-only information. It is good practice to observe this value after calibration. Monitoring the value over time will help you predict when the electrode will need to be replaced.
  • Page 21: Table 4-1 Oxidation-Reduction Potential Of Reference Solutions At Specified Temperature

    To prepare an ORP standardization solution, dissolve 0.1 g of quinhydrone powder (available as Honeywell part number 31103015 for a 2 oz. bottle) in 5 cc of acetone or methyl alcohol (methanol). Add this to not more than 500 cc of a standard pH reference solution (buffer), about 1 part saturated quinhydrone to 100 parts buffer solution.
  • Page 22: Table 4-2 Zero (Standardization) Calibration Procedure

    Calibration Calibration Procedures ATTENTION: In Table 4-2, under the Press column: • Hold means to hold the button down until the display changes. • Momentarily means to press and release the indicated button. Table 4-2 Zero (Standardization) Calibration Procedure Step Operation Press Display...
  • Page 23: Operation

    Operation 5. Operation 5.1 Displays Overview The DirectLine® DL422 displays the ORP value and Zero Offset ORP value. The table below describes these parameters. Table 5-1 Online Parameter Descriptions Parameter Description Online ORP Measured ORP expressed with fixed whole number precision. Range: –1600 mV to +1600 mV Zero Offset ORP Zero Offset ORP value expressed with whole number precision.
  • Page 24: Diagnostic Error Messages

    Operation 5.2 Diagnostic Error Messages When a diagnostic error or status condition occurs, the Online Display alternates between measured ORP and a text message. Table 5-3 Online Diagnostic Errors What you see What it is What to do CNFG Data error detected. Reset unit or cycle power.
  • Page 25: Unit Reset

    Operation 5.3 Unit Reset Overview Unit Reset initializes all of the DirectLine® Sensor’s calibration and configuration data to factory default values. Procedure • From the Online ORP display, press and hold the buttons simultaneously until the “rSEt” appears on the display (minimum of 10 seconds). •...
  • Page 26: Spare Parts

    Field Wiring connector The Field Wiring Connector is an all-plastic screw terminal M12 female type that can be purchased directly from Honeywell or from multiple vendors including: Turck Industries Part Number B8141-0 for a M12 field wiring connector that accommodates customer supplied cable.
  • Page 27: Sales And Service

    HONEYWELL S.A.I.C. 300 Yorkland Blvd. PO BOX 138 Naviglio A.S. BELGRANO 1156 NORTH YORK, Milnerton 7435 ITALY (Honeywell Turkey A.S.) BUENOS AIRES ONTARIO REPUBLIC OF SOUTH Tel. : 39 02 92146 1 Emirhan Cad No 144 ARGENTINA M2J 1S1 AFRICA Barbaros Plaza C.
  • Page 28 DirectLine® DL422 Sensor Module User Manual 1/03...
  • Page 30 Industrial Measurement and Control Honeywell 1100 Virginia Drive Fort Washington, PA 19034 www.honeywell.com/imc 70-82-25-107 0103 Printed in USA...

Table of Contents