2.3

Setting the Operating Parameters

Input via the numeric keypad:
The desired value is entered via the numeric keypad. It is displayed on the respective line. If an
incorrect value is entered by mistake, the value can be deleted by pressing the CL key.
2.3.1
Exposure time
Press the F4 e key. The set-point value display of the minutes/seconds is displayed inversely.
Enter the desired exposure time, confirm the set exposure time via the OK key, and the
clock symbol e subsequently appears.
If 0 is entered as the time, the timer is switched off and the high voltage can only be
switched on and off via the X-RAY ON and X-RAY OFF button.
(Special version for Australia:
Press the F1 key [mm'ss''] or (s) to toggle between the sec. display and the min/sec. display
for the exposure time.
Copyright by GE Sensing & Inspection Technologies GmbH
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
0 cannot be entered, the input value must be greater than 0.0.
The maximum exposure time is 30 min.)