    Order Codes ....................10     Dimensions ....................11     EU Declaration of Conformance ..............12   Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com page 2 KSK K03/0316...
  • Page 3: Note

     Operating Instructions 4. Regulation Use Any use of the Plastic Flow Meter, model: KSK, which exceeds the manufacturer’s specification, may invalidate its warranty. Therefore any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage.
  • Page 4: Operating Principle

    5. Operating Principle Kobold Plastic Flow Meters and Switches, model KSK, are based on the well known suspended float principle. They are used for measuring and monitoring flows in closed pipes. The media flows, from below, through a conical plastic measuring tube. This raises the float and the flow rate can be read off against scale.
  • Page 5: Electrical Connection

    Attention! The stated electrical parameters of the contact may not be exceeded, even for a short period of time. For inductive or capacitive loads, we recommend the use of contact protection measures respectively the application of a contact protection relay. KSK K03/0316 page 5...
  • Page 6: Electronic Contact (Option)

    After connecting the external devices, and adjusting the switch housing to the desired switch points, all the connection work is completed. The unit is ready for operation. page 6 KSK K03/0316...
  • Page 7: Operation

    9. Maintenance If the medium to be measured is clean, the series KSK is virtually maintenance- free. If deposits form on the inner housing or parts, periodic cleaning of the unit is recommended. Remove the units from the piping with a suitable tool; clean the flow meter with a suitable cleaning agent or make use of an ultrasonic bath.
  • Page 8: Technical Information

    10. Technical Information Materials Measuring tube: Trogamide T (KSK 1..) or polysulfone (KSK 2..) or PVDF (KSK 3..) not transparent, but opaque translucent Float: PVDF O-rings: EPDM (KSK-1../KSK-2..) FPM (KSK-3..) Max. operating pressure: PN 10 Max. operating temp.: KSK 1... max. 60 °C (0...60 °C) KSK 2...
  • Page 9 Weight with plug: 16 g Output signal (with LED at the top) Float above contact across PIN 1 and PIN E: Float below contact across PIN 1 and PIN E: 9 - 24 V LED out KSK K03/0316 page 9...
  • Page 10: Order Codes

    KSK - 1015... KSK - 2015... O0= without contact S0= 1 N/O contact 2.5 - 30 KSK - 1025... KSK - 2025... KSK - 3025...* SS= 2 N/O contacts 5 - 50 KSK - 1050... KSK - 2050... KSK - 3050...* K16= PVC-glue-in connection ...
  • Page 11: Dimensions

    12. Dimensions KSK K03/0316 page 11...
  • Page 12: Eu Declaration Of Conformance

    13. EU Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Plastic Flow Meter Model: KSK-... to which this declaration relates is in conformity with the standards noted below: EN 61000-6-3:2011-09 Electromagnetic compatibility, Interference emission living quarters...