Connection The Condensation Discharge Hose To The Interior Unit; Connection The Condensation Drainage Hose For The S-Ja2518 Models - Qlima S-JA2518 Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

Indoor unit
Connective cable
Drain hose
G
ATTENTION
Copper lines must be insulated independently from each other.
G
ATTENTION
Always use the highest care when bending the piping. Make sure that the piping always is
bent and not buckled. In case of a buckled pipe: replace the complete piping or the buckled part,
as this is a potential refrigerant leak and may cause damage to the air conditioner.
8. CONNECTION THE CONDENSATION DRAINAGE HOSE FOR THE S-JA2518
MODELS
8.1

Connection the condensation discharge hose to the interior unit.

Connect the included condensation drainage hose to the interior unit by sliding the hose over the hose nip-
ple on the interior unit. Ensure that the condensation drainage hose always runs downwards and do not
hang the end in the water. See fig. 15.
Always run the condensation drainage hose under the coolant pipes to prevent that the condensation tray
from overflowing.
CAUTION
• Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the unit.
• Run the drain hose sloped downward over the whole length to drain out the condensed water
smoothly.
Figure 15
4
30
30
Q_instal_S-JA2518 ('17) V2.indd 30
Ponding box
Pipe room
Connective pipe
Wrapping belt
Figure 14
Do not block water flow by a rise.
Do not put the end of drain hose
into water.
30-10-17 14:42