Electrical system overview, P 524EFI
1
1. Main fuse, 20 A
2. Battery
3. Relay
4. Safety switch for the seat
5. Light switch
6. Headlights
7. Hour meter
8. Microswitch for the hydrostatic transmission
9. Fuse holder
10. Ignition lock
11. Power outlet, 12 V
Warning lamps on the control panel,
P 524EFI
The engine on model P 524EFI has Electronic Fuel
Injection system. 2 lamps on the control panel show if
there are problems with the engine.
CAUTION: If a lamp on the control panel
comes on, stop the engine and refer to
Troubleshooting on page 40 .
A: Engine malfunction
B: Low oil pressure
6
2
11
10
9
3
4
5
A
B
Hour meter
The hour meter shows how many hours the engine has
run. The time with ignition on but engine off is not
registered. The last digit shows tenths of an hour (6
minutes).
Power outlet
The voltage of the power outlet is 12 V. The power outlet
To replace a fuse on page 28 .
has a fuse, see
Set the power outlet to on and off with the power switch
found on the control panel.