Led Light(S) Do Not Come On When Light Key Is Pressed; No Air/Water Mixture Coming From A Jet - Sunrise spas Classic Collection Series Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

LED Light(s) Do Not Come On When Light Key is Pressed

Probable
Light fuse blown in spa pack
cause #1:
Action:
Locate and test/replace light fuse in spa pack Call dealer if problem persists.
Probable
In -line or on board fuse blown in LED controller
cause #2:
Action:
Locate and test/replace light fuse in LED control box.

No Air/Water Mixture Coming From a Jet

Probable
Air control is closed
cause #1:
Action:
Open air control
Probable
Water volume through jet is too low to draw air
cause #2:
Action:
Increase water volume by turning jet face
Probable
Adjustable jet internal is loose.
cause #3:
Action:
Tighten jet internal
Probable
Jet internal is broken or damaged
cause #4:
Action:
Replace jet internal with another one from the spa or with a new one.
Probable
Debris inside the jet internal
cause #5:
Action:
Remove the internal, inspect for debris, remove debris and re-install. Test
72