CONVERSION FROM SINGLE SERVICE TO
3-SERVICE
1. Remove the jumper wire from J51 (Area 1) to J88 (Area 2)
2. Remove the jumper wire from J52 (Area 1) to J62 (Area 2)
3. Move the jumper wire attached to J60 from J36 in Area 3 to J45 in Area 4. (J60 to J45)
4. Move the jumper wire attached to J41 from J12 in Area 3 to J79 in Area 4. (J41 to J79)
5. Set DIP Switches A2 and A5 to OFF.
6. Terminal block must be wired according to the 3-Phase illustration on the wiring diagram
1. Line 1 – Brown
2. Neutral - Blue
3. Line 2 – Brown
4. Line 3 - Brown
Power Up Screen
Each time the system powers up, a series of numbers is displayed. After the start-up sequence of numbers, the system
will enter Priming Mode. Next, refer to the User Guide for your keypad at the back of this manual.

Wire Size and Over Current Protection

Total Ampere Rating of
16
DOC: OM-SUNRISE-18E
Minimum Wire Size
Power System
Use Copper ONLY
With 90°C Insulation
OA to 16A
16A to 20A
20A to 24A
24A to 28A
28A to 32A
SRBP21, SRBP21X & SRBP21MS
Spa Pack - 3-Service
Ampere Rating of
RCD Circuit-breaker
#12 AWG
#10 AWG
#10 AWG
#8 AWG
#8 AWG
European Sunrise Spas 2018 Owner's Manual
20
25
30
35
40