ELECTRICAL CONNECTION
GENERAL INFORMATION
A. LOCATING A CONDUIT WITHIN A CONCRETE PAD
B. SUPPLY CABLE ENTRY INTO SPA EQUIPMENT AREA
You may enter the spa cavity at any other point around spa provided you have reviewed the location and
determined there is no interference. You may also decide to enter at an adjoining wall (depending on the
positioning of the spa) and route a conduit along the spa kicker. Ask your electrician for his/her advice in
these matters.
In all cases the best side for entry of the supply cable is the side to your left when you are standing at the
equipment panel.
Right side entry is possible; however, this may involve additional supply cable, parts and time.

HOW TO PASS THE CABLE THROUGH THE SPA ENCLOSURE

Polysteel Frame with Polyethylene Bottom and Polysteel Panels
a) You can choose to notch the polysteel panel so you can pass the cable/conduit through and still be able to
remove/replace the panel for servicing. You should consider securing the cable or conduit to the spa's metal
frame where cable/conduit passes through the cabinet.
b) You may also route a cable up under the corner. The curved panel is flexible enough and there is enough
space to run the cable this way. Removing the corner may help you to do this easier.
c) On a concrete pad where you have a conduit or cable coming up within the perimeter of the spa, you can
easily cut an opening in the polyethylene bottom to access the cable or conduit/wires. See above table for
recommended opening location.
You may wish to insulate any opening or cut-out you make in the spa's cabinet panel or corner or bottom to keep cold
air and small animals out.
12
DOC: OM-SUNRISE-18E
If your intent is to bring a conduit and power wires up under the spa we suggest that it
enter the spa cavity in the front, left corner; 6" (15cm) Dimension A in from the left
and 6" (15cm) Dimension B up from the front. See A & B on the diagram below. This
location will allow you to stay clear of spa pumps and other equipment while giving you
a short and easy access to the left side of the spa pack, where the electrical entry hole
and terminal block are located.