Jet(s) Do Not Come On When Pump Key is Pressed

Probable
Jet pump is not plugged into spa pack.
cause #1:
Action:
Plug pump in and test.
Probable
Jet pump fuse blown in spa pack.
cause #2:
Action:
Locate & test/replace pump fuse in spa pack. Contact dealer if problem persists.
Probable
Jet pump is not primed.
cause #3:
Action:
Shut off spa and allow trapped air to escape. Restart spa & check jet pump operation. If
problem persists bleed air at pump directly by opening union on pump until all entrapped air is
released. Retest.
Probable
Individually adjustable volume jets are adjusted to low volume.
cause #4:
Action:
Turn face of specific jet to increase water volume.
Probable
Air control is closed. No visible air/water mix.
cause #5:
Action:
Open air control to increase air/water mix.
Probable
Pump has overheated and tripped internal thermal overload.
cause #6:
Action:
Wait for pump to cool & listen for "snap" sound as overload resets. Pump should restart.
Contact dealer if problem persists.
Probable
Pump is not pumping due to broken part inside (motor works, pump is primed but there is no
cause #7:
water movement from pump).
Action:
Contact dealer for service.