Leds "L1" And "L2 - Siemens SIMATIC NET Operating Instructions Manual

Network components
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Description of the device
3.7 LED displays
3.7.4

LEDs "L1" and "L2"

The "L1" and "L2" LEDs indicate the current range of the power supply at connectors "L1"
and "L2".
The colors of the "L1" and "L2" LEDs have the following significance:
● Green
The connected voltage is higher than the monitoring voltage.
● Orange
The connected voltage is higher than 8 V, however lower than the monitoring voltage.
● Off
The connected voltage is lower than 8 V.
LED "L1"
Green
Green
Off
Green
Orange
Orange
Note
Value of the monitoring voltage
For a description of the monitoring voltage, refer to the section "Technical data (Page 43)".
30
LED "L2"
Connector "L1"
Off
Higher than the monitoring voltage
Green
Higher than the monitoring voltage
Green
Lower than 8 V
Orange
Higher than the monitoring voltage
Orange
higher than 8 V,
but lower than the monitoring voltage
Green
higher than 8 V,
but lower than the monitoring voltage
Power supply
Connector "L2"
Lower than 8 V
Higher than the monitoring voltage
Higher than the monitoring voltage
higher than 8 V,
but lower than the monitoring voltage
higher than 8 V,
but lower than the monitoring voltage
Higher than the monitoring voltage
Operating Instructions, 10/2013, C79000-G8976-C297-02