3.7.3

LEDs "S1" and "S2"

Meaning in display and configuration mode A
In display and configuration mode A, the LEDs "S1" and "S2" indicate the configuration of
the startup time.
Pressing the "SET" button
starting from configuration 0
-
Press once
Press twice
Press three times
Meaning in display and configuration mode B
In display and configuration mode B, the LEDs "S1" and "S2" indicate the configuration of
the monitoring voltage.
Pressing the "SET" button
starting from configuration 0
-
Press once
Press twice
Press three times
SCALANCE XC100-4OBR
Operating Instructions, 10/2013, C79000-G8976-C297-02
Configuration
Startup time
0
30 s
1
60 s
2
120 s
3
300 s
Configuration
Monitoring voltage
0
12 V (-10%)
1
24 V (-20%)
2
24 V (-10%)
3
48 V (-20%)
Description of the device
3.7 LED displays
"S1" LED
"S2" LED
Off
Off
Off
Lit
Lit
Off
Lit
Lit
"S1" LED
"S2" LED
Off
Off
Off
Lit
Lit
Off
Lit
Lit