HECKING THE FUEL CHAMBER
DOOR
7 Cleaning and servicing the heating system – Procedure
3
Figure 7/19 - Cleaning the air control unit
2.
Lift up on the cladding (2) of the air control unit (1 + 3) and pull it
out towards the front.
3.
Use a fine brush and a vacuum cleaner to remove dust deposits
from the air control unit (1 + 3).
4.
Carefully press on the two rotary vanes behind the actuators and
make sure that these are movable.
5.
Close the air control unit in reverse order.
The air control unit is cleaned.
I
NSPECTING THE DOOR SEALS FOR LEAKS
Important!
Observe the "Generally applicable safety instructions" in this
section.
1.
Allow the fire in the boiler to burn out and cool off.
2.
Open the fuel chamber door.
See "Cleaning the fuel chamber" in "Cleaning the fuel chamber
and ash compartment" in this section.
Figure 7/20 - Checking the fuel chamber door for leaks
1
2
1
2