4.6 Lighting and reloading the HDG Euro........30...
Page 4
Operation Manual HDG Euro V3.0 with HDG Lambda Control 1 - Content Cleaning and maintaining the HDG Euro ......39 5.1 Cleaning and maintenance plan.
1.1 Introduction This Operation Manual contains important information for proper Safe and simple and safe operation of the HDG Euro V3.0 with HDG Lambda Control 1. operation Following these instructions serves in avoiding dangers, preventing repair costs and downtimes, maintaining reliability and extending the service life of the heating system.
6 Troubleshooting ... how to rectify faults in the heating system. 7 Commissioning the HDG Euro ... how the HDG Euro is to be put into initial service. 8 Notes on dismantling and ... what has to be considered when dismantling and disposing of disposal the HDG Euro.
Proper and improper manner of operation The HDG Euro V3.0 with HDG Lambda Control 1 is designed to burn Application of the untreated wood in the form of split logs up to 500 mm (19"), pressed...
HDG Euro V3.0 with HDG Lambda Control 1 Figure 3/3 - HDG Euro V3.0 with HDG Lambda Control 1 Inside the HDG Euro V3.0 with HDG Lambda Control 1, fuel which has been manually placed in the fuel chamber (1) and ignited is degassed through the addition of primary air.
8 “Reload” button 9 Unlocking knob for the safety temperature limiter (STB) The HDG Lambda Control 1 control panel is located on the top of the HDG Euro V3.0 with HDG Lambda Control 1. Using the control panel, you can regulate the HDG Lambda Control 1 system and call up information on the current operating status.
80˚C. The fault is automatically reset. 4.2 Initialising the system Requirements In order for the HDG Euro to be switched on, it must first have been put into service by an authorised specialist. ✎ See chapter “7 Commissioning the HDG Euro”.
4 Using the HDG Euro – Displaying information 4.4 Displaying information You can call up a variety of information on the display of the HDG Lambda Control 1. Certain information and settings can only be accessed and changed in “Heat production on” or “Heat production off”.
4 Using the HDG Euro – Switching off the HDG Euro for maintenance or repair work Hold the cleaning door open until the indicator lamp “Heat production on” (1) lights up and the message “Heat production on” appears in the display (2).
6 Troubleshooting – How to proceed 6 Troubleshooting If a fault occurs in the HDG Euro, it will be indicated in the display of the HDG Lambda Control 1 and by the indicator lamp on the HDG Lambda Control 1 control panel.
Page 74
7 Commissioning the HDG Euro – Commissioning the HDG Euro Grate lifter In the HDG Euro V3.0 with HDG Lambda Control 1 for log wood, the grate lifter is already installed in a horizontal position! The position of the grate lifter (2) can be changed in order to correct the gas quantity during degassing and thus avoid pulsating (sudden igniting due to lack of oxygen) or insufficient flue gas temperatures.
Only dismantle the boiler after you have thoroughly read the manual. The HDG Euro can be dismantled as follows. Allow the fire in the HDG Euro to burn out and for the system to cool off. Danger! Danger from electrical current or voltage The HDG Euro can only be completely de-energised by switching off the mains circuit breaker or the emergency heating switch.