MTU 20V4000M93 series Operating Instructions Manual page 193

Table of Contents

Advertisement

Draining oil
u
Remove plug screw (2) with sealing ring (1)
and drain off oil into a suitable container.
Removing automatic oil filter
Note:
Clean interface between automatic oil filter
and coolant distribution housing.
1.
Attach automatic oil filter (1) to crane with a
lightly tensioned lifting strap.
2.
Remove screws (2).
3.
Remove automatic oil filter (1) from coolant
distribution housing (3).
4.
Collect any oil that runs out.
5.
Remove O-rings (4).
6.
Seal openings on coolant distribution housing
(3) with suitable covers.
MS150048/05E 2018-03 | Oil Filtration / Cooling | 191