2.5
2.5 Integration diagram for mono energy heat pump operation with 2
heating circuits, domestic hot water preparation according to the flow
principle with a solid fuel boiler, solar heating and domestic hot water

preparation.

Central domestic hot water preparation according to the flow principle
Mono energy heat pump heating system with 2 heating circuits, domestic hot water preparation according to the flow principle with
a solid fuel boiler, solar heating and domestic hot water preparation.
A-XXIV
Pre-configuration
Setting
Mono
Operating mode
energy
Heating circuit 1
Yes
Heating circuit 2
Yes
Cooling function
No
passive
Domestic hot water
Yes
preparation
Swimming pool
water
No
preparation
A separating plate integrated into
the combo tank in combination
with a 3-way valve prevents
mixing losses between the
heating and the hot water zones.
With external charging, heat riser
pipes distribute the external
energy to the supplementary
heating system and the domestic
hot water preparation on the
basis of the temperature.
A flange connection enables the
additional installation of the RWT
750 solar heat exchanger.
For solid fuel boilers with an
output of more than 10 kW, we
recommend that the flow of the
solid fuel boiler be connected
directly to the domestic hot water
preparation inlet of the PWD.