Conversion kits are to be supplied and installed by a licensed installer or the Hoval after-sales service. Maintain the air supply in the With proper handling your Hoval system will guarantee boiler installation room you a comfortable domestic climate for many years.
The electrical connection is to be made by an electrician. The circuit diagram is inside the cover of the controller. General ® Hoval gas boilers TopGas (80) are fitted with automatic control and safety systems. They are normally in operation from the start to the end of the heating period.
Page 4
Important information 4 203 413 / 00 Important information Erection and assembly instructions • The installer has handed you the installation instructions. Look after this important technical If you smell gas, close the gas shut- document in order that it can be referred to later on off cock before the meter and call site by the after-sales service fitter.
Commissioning / decommissioning 4 203 413 / 00 Boiler cleaning Maintenance and checking Preparations for commissioning In the case of a newly installed system, commissioning See page 9 for maintenance and checking information. may only be carried out by a specialist. The installation check must be carried out in full.
Page 6
Control 4 203 413 / 00 Boiler control ® ® User-dependent settings (e.g. room temperature) are made at the TopTronic RS-30 or TopTronic 1B/133B. ® ® This is preferably installed in the living room (RS 30) or in the boiler (TopTronic 1B/133B).
Page 7
Boiler operating elements 4 203 413 / 00 Operating elements * also supplied without electronic heating controller Legend Function O = Off I = On SYSTEM SYSTEM 1. Mode selection switch Boiler operating Boiler and burner are inoperative ON/OFF Attention: No anti-freeze - Controls the internal boiler functions 2.
Page 8
Boiler operating elements 4 203 413 / 00 Legend Function - The desired night-time room temperature can be set here. 5. Setpoint value Medium setting 14°C ±6°C "Reduced” The heating program can be selected here: 6. Program switch Heating and hot water filling ”OFF”. Frost protection guaranteed The room temperature night-time setting is also effective during the day.
Page 9
Nevertheless, carry ® boiler such as this Hoval TopGas , in order to achieve out the following checks in the course of optimal annual efficiency. You can take out a...
Page 10
Please note! If you are unable to rectify the In the event of operating faults, carry out fault, please contact your the checks according to the above heating installer or the Hoval checklist. after-sales service.
Page 11
How to save energy! 4 203 413 / 00 The room temperatures When there is a draught, Keep in valuable heat with and heating system it’s not only unpleasant but insulation. it also means a loss of operating times have a decisive influence on fuel heat energy.
• Your heating system is always optimally set, saving take out a Hoval After-Sales Maintenance Contract. heating costs and protecting the environment. With this agreement the Hoval After-Sales Service •...