Download Print this page
Hoval TopGas 80 Operating Instructions Manual

Hoval TopGas 80 Operating Instructions Manual

Advertisement

Operating instructions
®
TopGas
(80)
4 203 413 / 00
Hoval LTD
Northgate
Newark
Nottinghamshire NG24 1JN
Phone: 01636 672 711
Fax: 01636 673 532
To be completed by the heating specialist:
Order No.:
Boiler type:
Set to:
Natural gas H
Heating pump type:
Heating controller type:
Mixing unit type:
Separate calorifier type:
Calorifier sensor
Outdoor temperature sensor
Room temperature sensor
Combustion air supply
Heating system calculation basis
Lowest outside temperature
Heat requirements:
Max. feed temperature:
Important telephone numbers
Heating system installer
Sanitation plumbing installer
Electrical system installer
Fuel supplier
Chimney sweep
Hoval Export
Austrasse 70
Principality of Liechtenstein
Phone: +423 399 2400
Fax:
+423 399 2618
Export@hoval.com
Subject to changes
Natural gas L
Liquid gas
Thermostat
Room
Outdoor
°C
kW
°C

Advertisement

loading
Need help?

Need help?

Do you have a question about the TopGas 80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hoval TopGas 80

  • Page 1 °C Max. feed temperature: Important telephone numbers Heating system installer Sanitation plumbing installer Electrical system installer Fuel supplier Chimney sweep Hoval LTD Hoval Export Northgate Austrasse 70 Newark Principality of Liechtenstein Nottinghamshire NG24 1JN Phone: +423 399 2400 Phone: 01636 672 711...
  • Page 2: Safety Information

    Conversion kits are to be supplied and installed by a licensed installer or the Hoval after-sales service. Maintain the air supply in the With proper handling your Hoval system will guarantee boiler installation room you a comfortable domestic climate for many years.
  • Page 3: Precautionary Information

    The electrical connection is to be made by an electrician. The circuit diagram is inside the cover of the controller. General ® Hoval gas boilers TopGas (80) are fitted with automatic control and safety systems. They are normally in operation from the start to the end of the heating period.
  • Page 4 Important information 4 203 413 / 00 Important information Erection and assembly instructions • The installer has handed you the installation instructions. Look after this important technical If you smell gas, close the gas shut- document in order that it can be referred to later on off cock before the meter and call site by the after-sales service fitter.
  • Page 5: Maintenance And Checking

    Commissioning / decommissioning 4 203 413 / 00 Boiler cleaning Maintenance and checking Preparations for commissioning In the case of a newly installed system, commissioning See page 9 for maintenance and checking information. may only be carried out by a specialist. The installation check must be carried out in full.
  • Page 6 Control 4 203 413 / 00 Boiler control ® ® User-dependent settings (e.g. room temperature) are made at the TopTronic RS-30 or TopTronic 1B/133B. ® ® This is preferably installed in the living room (RS 30) or in the boiler (TopTronic 1B/133B).
  • Page 7 Boiler operating elements 4 203 413 / 00 Operating elements * also supplied without electronic heating controller Legend Function O = Off I = On SYSTEM SYSTEM 1. Mode selection switch Boiler operating Boiler and burner are inoperative ON/OFF Attention: No anti-freeze - Controls the internal boiler functions 2.
  • Page 8 Boiler operating elements 4 203 413 / 00 Legend Function - The desired night-time room temperature can be set here. 5. Setpoint value Medium setting 14°C ±6°C "Reduced” The heating program can be selected here: 6. Program switch Heating and hot water filling ”OFF”. Frost protection guaranteed The room temperature night-time setting is also effective during the day.
  • Page 9 Nevertheless, carry ® boiler such as this Hoval TopGas , in order to achieve out the following checks in the course of optimal annual efficiency. You can take out a...
  • Page 10 Please note! If you are unable to rectify the In the event of operating faults, carry out fault, please contact your the checks according to the above heating installer or the Hoval checklist. after-sales service.
  • Page 11 How to save energy! 4 203 413 / 00 The room temperatures When there is a draught, Keep in valuable heat with and heating system it’s not only unpleasant but insulation. it also means a loss of operating times have a decisive influence on fuel heat energy.
  • Page 12: Maintenance Contract

    • Your heating system is always optimally set, saving take out a Hoval After-Sales Maintenance Contract. heating costs and protecting the environment. With this agreement the Hoval After-Sales Service •...