TRUE RESIDENTIAL REFRIGERATION
UPRIG HT ANTI-TIP BR ACKE T INS TALL ATION
ANTI-TIP BR ACKE T KIT:
• One (1) anti-tip bracket (Figure 1.1)
• Four (4) masonry 3/16" screws
• Eight (8) wood #12 – 2" screws
• Twelve (12) 1/4" washers
FOR ALL FULL SIZE RESIDENTIAL MODELS, THE ANTI-
TIP BRACKET ENGAGES WITH THE REAR LEVELING
LEGS TO SECURE THE UNIT. FOLLOW THESE STEPS
TO SECURE THE BRACKET BEFORE MOVING THE
UNIT INTO FINAL OPERATING POSITION.
1. Determine final location of the unit. For a FLUSH
install, measure back 24-31/32" (Dimension A)
from the surrounding cabinetry. For a PROUD
install, measure back 22-31/32" (Dimension B)
from the surrounding cabinetry. For either type of
install, place the anti-tip bracket centered in the
rough opening.
30 INCH UNIT
22 31/32"
583mm
PROUD INSTALL
R
9 9/32"
236mm
C L
2. Using the bracket as a guide, drill pilot holes into the
wall/floor. It is recommended to secure the bracket
to as many floor joists and wall studs as possible.
3. Using the provided screws and washers, secure the
bracket to the wall/floor. Adjust the rear rollers to
just above their lowest position and move the unit to
its final position. Raise the rear rollers a minimum
of 1/8" to engage the bracket.
FIGURE 1.1 - ANTI-TIP BRACKET
TR-30REF-R-SG-A
N O T E : D I M E N S I O N S M AY VA R Y B Y ±
9 9/32"
236mm
C L
987036
5.19.17 AL
/
"
1
8
24 31/32"
634mm
FLUSH INSTALL
30 INCH COLUMNS
13