Test Program
Procedure of Test Program
Dis play on
No.
t he s c reen
8:88
0
05 or
Turbidity
1
value
04/Temper-
2
ature value
03
3
02
4
01
5
F*
6
Process
Power on, stand by
Intialization
Open inlet valve and feeds with 1.9L wate
Running fan closed after 10 seconds
Inlet Valve
Run washing pump and 10s later run heating
Washing Pump
element until the water temperature reaches 57℃. Then the
and Heating
machine will pause.
Element
Press Program button to jump into the next step.
washing pump for 10s, dispenser will
Washing Pump
act for 45s in this step.
and Dispenser
static
static 30s.
Drain for 30s.
Drain Pump
Buzz one sound, stop, and stand by.
finish
(for models controlling water filling by flowmeter)
Description