Download Print this page

Savant SLN-88BT Quick Reference Manual page 2

Advertisement

RS-232 Wiring
Controller RJ-45 (RS-232) Plug Pinouts
1 (Not Used for RS-232)
5 TXD (RS-232)
2 (Not Used for RS-232)
6 RXD (RS-232)
3 (Not Used for RS-232)
7 (Not Used for RS-232)
4 GND (RS-232)
8 (Not Used for RS-232)
Debug Wiring
Controller RJ-45 (RS-232) Plug Pinouts
1 (Not Used for RS-232)
5 RXD (RS-232)
2 (Not Used for RS-232)
6 TXD (RS-232)
3 (Not Used for RS-232)
7 (Not Used for RS-232)
4 GND (RS-232)
8 (Not Used for RS-232)
Important
If you are using RJ-45 to DB-9 adapters not supplied by Savant, be sure to terminate any wires
required for communication/control within the adapter. Ensure that all wires required for
communication/control are not terminated in the connecter. Also, ensure that the unused wires in
the connector are cut to prevent them shorting out, as they are still terminated in the RJ-45
connector on the controller side
IR Port Layout and Pinouts
Copyright © 2013 Savant Systems LLC, SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
Apple®, iPad®, iTunes®, iPod touch®, iPod® Classic and iPod nano® are registered trademarks or trade names of Apple Inc.
Savant Systems, LLC reserves the right to change product specifications without notice.
Savant SmartLink 8
Quick Reference Guide
+
Out
-
IR
+
In
-
Document based upon target specifications. Specifications subject to change prior to final product release.
(SLN-88BT)
Interconnect the Network
The SLN-88BT requires business class/commercial grade network equipment in order to handle
the IP traffic between Savant SmartSystems™ network equipment. When configuring the
network ensure that all of the connected Savant units (including SLN-88BT, HST-series and
SVR-series) are on the same local area network (subnet or LAN).
Network Changes Require Rebooting the SLN-88BT
The embedded processor used in the SmartLink needs to be rebooted after switching to a new
network with a new IP address range. If you do not reboot, the SLN-88BT will not sense the
network and IP address changes. The Status LED on the front panel of the SLN-88BT will start
to flash.
Replacing or Checking Fuse
To replace or check the fuse on the SLN-88BT, do the following:
1. On the input power block, open the cover (hinged) to access the fuse cartridge. Refer to the
illustrations below.
2. Using a thin, flat tool remove the red cartridge.
Important: Before removing the fuse, note how and where the fuse is mounted in the
cartridge. The fuse must be replaced at the same location. Refer to the
illustration below.
3. Remove the existing fuse and replace with a new one.
4. Re-install the cartridge. Note that the cartridge fits in only one direction.
Horizontal Mounting
ELECTRIC SHOCK:
Additional Documentation
Additional Documentation is available at:
Knowledge Base > Savant Hardware
Vertical Mounting
The 100-240V AC, 50-60 Hz source power poses an electric shock
hazard that has the potential to cause serious injury to installers and
end-users.
dealers.SavantSystems.com
009-1000-00
SLN-88BT-00
080813