Si04-955

9. Exchange of Drain Hose (Piping Direction)

Procedure
Step
1
Pull out the drain hose.
2
Pull out the drain plug
from the left side with
pliers.
3
Push the drain plug into
the right hole with a
hexagonal wrench
(4 mm).
4
Insert the drain hose
into the left hole firmly.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Drain plug
Drain plug
Drain hose
Exchange of Drain Hose (Piping Direction)
Drain hose
(R5388)
(R5389)
Caution
Do not push the drain plug
with a sharp object like a
screwdriver. (The drain plug
can be damaged and that
causes leakage of water.)
(R5390)
(R5391)
Points