Step 5 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End

7.9 Opening the Cover Plate of an RRU Cabling Cavity

This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
Step 1 Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2 Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the RRU cabling
cavity, and open the cover plate, as shown in
Figure 7-21 Opening the cover plate of the RRU cabling cavity
(1) Cover plate
(4) Cable trough for the power cable
Step 3 Loosen the screws on the clip using an M4 Phillips screwdriver, and open the clip, as shown in
Figure
Issue Draft A (2014-10-31)
NOTICE
7-22.

Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.
Figure
7-21.
(2) Cabling cavity
(3) Clip
(5) Waterproof block (6) Cable trough for the fiber optical cable
7 Installing RRU Cables
54