Table 3-2 Zxsdr Rsuc Capacity Indices - Zte ZXSDR RSUC User Manual

Radio system unit of cdma with 1t2r
Hide thumbs Also See for ZXSDR RSUC:
Table of Contents

Advertisement

-48V DC Voltage range: -40V~-57V.
l
Power Consumption
In the case of 1S-1T, 4C/S, 15W/C, the total power consumption of the equipment is
270 W.
3.3.3 Capacity Indices
ZXSDR RSUC Capacity Indices is shown as

Table 3-2 ZXSDR RSUC Capacity Indices

Item
1
2
3
3.3.4 Temperature and Humidity
Temperature: -20 ℃~+45 ℃. The change frequency must be less than 0.5 ℃/min.
Relative humidity: 5% ~95%
3.3.5 Environmental Classes
l
Grade Of Protection: IP30
l
Grounding Requirements: Joint grounding resistance less 1W; BTS grounding
resistance less 5 W.
l
Noise: Noise of working environment: less 65 dBA
3.3.6 Reliability Indices
l
Mean Time Between Failures (MTBF) : > 100,000 hours
l
MTTR (Mean Time To Repair): < 0.5 hour
l
Availability: > 99.999%
3.3.7 RF Indices
RF indices of the ZXSDR RSUC comply with 3GPP2 C.S0010-C, Recommended
Minimum Performance Standards for cdma2000 Spread Spectrum Base Station and
3GPP2 C.S0032-A, Recommended Minimum Performance Standards for CDMA2000
High Rate Packet Data Access Network.
Table 3-3
SJ-20101019140047-002|2012-03-15 (R1.1)
Carriers supported
8C 1X
8C DO
the Max 8C/1S-1T
illustrates the 800 MHz transmitter indices.
Chapter 3 Technical Descripition
Table 3-2
3-3
ZTE Proprietary and Confidential

Advertisement

Table of Contents
loading

Table of Contents