Ka-Band Block Upconverter May 2015, Rev. B Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
1.0 General 1.1 Equipment Description The 4115-41-212 Ka-band Block Upconverter converts 0.95 - 1.95 GHz up to 17.7 - 21.2 GHz in four selectable fixed bands. Front panel LEDs provide indication of DC Power and PLL Alarms. The L-band to RF gain is +30 dB.
Gain, band select, and internal 10 MHz frequency via Ethernet M&C or Gain, Band,10M Frequency Status/Control Connector PLL Alarm Red LED, External Contact Closure Power Green LED Technical Characteristics continued on page 5... 4115-41-212 Manual, Rev. B Page 4 05/07/15...
A switching, ±12, +24, +5 VDC power supply provides power for the internal assemblies. The 4115-41-212 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panels. See figure 2.5 for mounting dimensions.
2.2 M&C Commands The following tables summarize the commands and status queries applicable to the 4115-41-212 frequency converter. PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected. Table 2.0 - Model 4115-41-212 M&C Commands Table 2.0: Model 4115-41-212 M&C Commands...
2.3 M&C Queries Table 2.1 Model 4115-41-212 M&C Commands Table 2.1: Model 4115-41-212 M&C Queries Command Syntax Description Frequency Band {aaSB} Returns {aaSBx} where: x = 1 if band 1 is selected in = (950 to 1950 MHz) out = (1770 to 1870 MHz)
Each 4115-41-212 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your network manager. The 4115-41-212 is set at the factory with a static address that is written on a tag attached to the unit. The device server in the 4115-41-212 has a built in http based configuration manager that is used to configure network settings.
Enter the following address in a web browser to access the M&C web page: http://<ip address of 41xx>/serial/0/setup.htm where <ip address> is the IP address of the unit. Figure 2-C shows the web page from a model 4115-41-212 Upconverter. 4115-41-212 Manual, Rev. B...
“Connect To” dialog box. Select TCP/IP (Winsock) from the “Connect” using drop down menu. Enter the IP address of the 4115-41-212 in the “Host address:” field and 9999 in the “Port number” field. Figure 2-E shows an example of the Hyper Terminal settings required to access the SNMP configuration menu.
Page 13
SNMP traps are not implemented. The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server. 4115-41-212 Manual, Rev. B Page 13 05/07/15...
Page 14
Figure 2-F: Device Server Configuration Menu 4115-41-212 Manual, Rev. B Page 14 05/07/15...
RS422/RS485 Data In+, RS232 Data In NOTE: Planning Ethernet Access It is recommended that IP knowledgeable customer personnel be consulted as a resource in the installation and use of the Ethernet access features of the Cross Technologies product. 4115-41-212 Manual, Rev. B Page 16...
NOTE: If a fuse continues to open, the power supply is most likely defective. 2.0.1 Connection to AC Input Power The 4115-41-212 is furnished with a pre-assembled AC power input cable as described below. 4115-4 4115-41-310 AC Power Input Connections...