Summary of Contents for Cross Technologies 4117-14
Page 1
Weather Resistant Unit March 2017, Rev. J Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
Ethernet M&C. In AUTO, the 10 MHz reference stays in external if the external level is in the +2 to +8 dBm range. The 4117-14 is powered by a 100-240 ± 10% power supply, and is mounted in a 8” W X 6” H X 16”...
1.2 Technical Characteristics TABLE 1.0 4117-14 Block Up/Downconverter Specifications** UPCONVERTER DOWNCONVERTER Input Characteristics (UHF, L) Input Characteristics (L, UHF) Impedance/Return Loss 50Ω / 14 dB Impedance/Return Loss 50Ω / 14 dB Frequency 0.2 to 0.4 GHz Frequency 1.2 - 1.4 GHz...
Page 5
(water, sleet, snow, etc.) but they are not designed to be “submerged under” water. If an extended temperature range is required, there is an Extended Temperature option (Option W21; -30˚C to +60˚C) available at an additional cost. Contact Cross for quote. 4117-14 Manual, Rev. J Page 5 03/27/17...
The 4117-14 Block Up/Downconverter consists of a 8”W X 6”H X 16”D Weather Resistant* enclosure. A switching, ± 12, +24, +5 VDC power supply provides power for the internal assemblies. The 4117-14 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panels. See Figure 2.5 for mounting dimensions.
Each 4117-14 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your network manager. The 4117-14 is set at the factory with a static address that is written on a tag attached to the unit. The device server in the 4117-14 has a built in HTTP based configuration manager that is used to configure network settings.
Page 8
In the left frame of the configuration manager click on Network to display the Network Settings screen. Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 192.168.192.47). Click apply settings in the left frame to apply the new settings in the network device. 4117-14 Manual, Rev. J Page 8 03/27/17...
“Connect To” dialog box. Select TCP/IP (Winsock) from the “Connect” using drop down menu. Enter the IP address of the 4117-14 in the “Host Address:” field and 9999 in the “Port Number” field. Figure 4-D shows an example of the Hyper Terminal settings required to access the SNMP configuration menu.
Page 10
SNMP traps are not implemented. The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server. 4117-14 Manual, Rev. J Page 10 03/27/17...
Page 11
Figure 4-E: Device Server Configuration Menu NOTE: Planning Ethernet Access It is recommended that IP knowledgeable customer personnel be consulted as a resource in the installation and use of the Ethernet access features of the Cross Technologies product. 4117-14 Manual, Rev. J Page 11...
Page 12
-20 dB Down Monitor 0.2 to 0.4 GHz SMA Connector, 50Ω SMA Connector, 50Ω L-Band Output UHF Input +2 - +8 dBm Input Loop-through. 1/4 - 20 Tapped Thru, 4 Places 12.00 15.5 15.875 7.50 4117-14 Manual, Rev. J Page 12 03/27/17...
Chassis Ground Summary Alarm Normally Closed Summary Alarm Common Summary Alarm Normally Open RS422/RS485 Data Out- Signal Ground RS422/RS485 Data In- RS422/RS485 Data Out+, RS232 Data Out RS422/RS485 Data In+, RS232 Data In 4117-14 Manual, Rev. J Page 13 03/27/17...
CAUTION: When checking or replacing the fuse, do not over tighten the fuse holder cap. This can displace the cap’s O-ring and the weatherproof seal will be lost. 2.5 Installation/Operation The 4117-14 is furnished with a pre-assembled AC power input cable as described below. 4117-1 4117-14 AC Power Input Connections...