Cross Technologies 3016-2124 Instruction Manual

Downconverter

Advertisement

Quick Links

Instruction Manual
RF MONITOR
ALARM
REMOTE POWER
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be
reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating
the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
F=23123.125
MENU
G=+10
Ref = AUTO-I
EXECUTE
C
T
ROSS
ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
Model 3016-2124
Downconverter
August 2012, Rev. 0
MODEL 3016
DOWNCONVERTER
C
ROSS
T
ECHNOLOGIES INC.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3016-2124 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cross Technologies 3016-2124

  • Page 1 EXECUTE ALARM REMOTE POWER Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
  • Page 2: Table Of Contents

    All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
  • Page 3: General

    1.1 Equipment Description The 3016-2124 Downconverter converts 21 to 24 GHz to 70 ± 18 MHz in 125 kHz steps (1 kHz opt -X1008). This unit combines a multi-band block downconverter with a 3-4 GHz to 70 MHz agile downconverter to obtain the wide tuning range.
  • Page 4: Technical Characteristics

    1.2 Technical Characteristics TABLE 1.1 3016-2124 Downconverter Specifications* Input Characteristics (RF) Impedance / Return Loss 50Ω /18 dB typ., 14 dB min. Frequency 21 to 24 GHz Noise Figure, max. 20 dB (max. gain) Input Level Range -50 to -30 dBm...
  • Page 5: Monitor & Control Interface

    A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option -Q) M&C Cable Diagram - Cross Technologies Frequency Converters Female DB-9 Male DB-9...
  • Page 6 Table 1.1 lists the status requests for the 2016-03 and briefly describes them. PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. TABLE 1.1 3016-2124 Status Requests TABLE 1.1 3016-2124 Status s Requests Status Requests Command Syntax*...
  • Page 7 C) Commands - Table 1.1 lists the commands for the 3016-2124 and briefly describes them. After a command is sent the 3016-2124 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where:...
  • Page 8: Environmental Use Information

    G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 3016-2124- Manual_Rev.0 Page 8 8/02/12...
  • Page 9: Installation

    2.1 Mechanical The 3016-2124 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 3016-2124 can be secured to a rack using the 4 holes on the front panel.
  • Page 10: Rear Panel Inputs & Outputs

    RF In program mode. Does not function adjusted. Does not function in the in the normal display mode normal display mode FIGURE 2.3 3016-2124 Front Panel Controls and Indicators 3016-2124- Manual_Rev.0 Page 10 8/02/12...
  • Page 11: Operation

    2.4 Operation 2.4.1 Installing and Operating the 3016-2124 Downconverter 1. Connect a -50 dBm to -30 dBm signal to RF IN, J2 (Figure 2.2, page 10). 2. Connect the IF OUT, J1, to the external equipment. 3. Connect 100-240 ±10% VAC, 47-63 Hz to AC on the back panel.
  • Page 12: Menu Settings

    If programming is initiated and no operator action takes place for approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 3016-2124- Manual_Rev.0 Page 12 8/02/12...
  • Page 13 During frequency, gain changes, the vertical movement will raise or lower the number in the direction of the arrows. b. For other functions such Mute on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 3016-2124- Manual_Rev.0 Page 13 8/02/12...
  • Page 14 Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to this: F = 23123.125 G=+10 Ref=AUTO=I Figure 2.5 gives the menu items and how to make changes. 3016-2124- Manual_Rev.0 Page 14 8/02/12...
  • Page 15 Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to this: F = 23123.125 G=+10 Ref=AUTO=I Figure 2.5 gives the menu items and how to make changes. 3016-2124- Manual_Rev.0 Page 15 8/02/12...
  • Page 16 Menu 8 Set RS-485 Address ADDRESS = 00 (option Q) SCROLL PUSH BUTTON Save? When “R” is selected or at SAVE SETTINGS? the end of the menu options SCROLL <> PUSH BUTTON FIGURE 2.5 Menu Display and Sequence 3016-2124- Manual_Rev.0 Page 16 8/02/12...
  • Page 17: Shiloh Road Alpharetta, Georgia

    ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com PRINTED IN USA 3016-2124- Manual_Rev.0 Page 17 8/02/12...