Cross Technologies 4115-300 Instruction Manual

Cross Technologies 4115-300 Instruction Manual

Ka-band block upconverter. weather resistant unit

Advertisement

Quick Links

Model 4115-300
Instruction Manual
Ka-Band Block Upconverter
Weather Resistant Unit
November 2015, Rev. H
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be
reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating
the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
C
T
ROSS
ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005 • FAX (770) 886-7964 • Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4115-300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cross Technologies 4115-300

  • Page 1 Weather Resistant Unit November 2015, Rev. H Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment.
  • Page 2: Table Of Contents

    All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
  • Page 3: General

    1.1 Equipment Description The 4115-300 Ka-band Block Upconverter converts 0.95 - 1.95 GHz up to 27.5 - 31.0 GHz in four selectable fixed bands. Front panel LEDs provide indication of DC Power and PLL Alarms. The L-band to RF gain is +30 dB.
  • Page 4: Technical Characteristics

    1.2 Technical Characteristics TABLE 1.0 4115-300 Block Upconverter Specifications** Input Characteristics Impedance / Return Loss 50Ω / 14 dB Frequency (GHz) 0.95 to 1.95 GHz Noise Figure, Maximum 20 dB maximum gain Input Level -40 to -15 dBm Output Characteristics Impedance / Return Loss 50Ω...
  • Page 5 8” Wide X 6” High X 16” Deep, Weatherized Resistant* Enclosure 100-240 ±10% VAC, 47-63 Hz, 25 Watts Maximum, Power FCI Clipper Series CL1M1102, Weather Resistant Connector. **+10˚C to +40˚C; Specifications subject to change without notice. © 2015 Cross Technologies, Inc. 4115-300 Manual, Rev. H Page 5 11/16/15...
  • Page 6: Installation

    The 4115-300 Ka-Band Upconverter consists of a 8”W X 6”H X 16”D Weather Resistant* enclosure. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 4115-300 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panel. (See Figure 2.5 for mounting dimensions.)
  • Page 7: M&C Commands

    The following tables summarize the commands and status queries applicable to the 4115-300 frequency converter. PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected. Table 2.0 Model 4115-300 M&C Commands Table 2.0: Model 4115-300 M&C Commands Command Syntax Description where:...
  • Page 8: M&C Queries

    2.3 M&C Queries Table 2.1 Model 4115-300 M&C Queries Table 2.1: Model 4115-300 M&C Queries Queries Syntax Description Frequency Band {aaSB} Returns {aaSBx} where: x = 1 if band 1 is selected in = (950 to 2050 MHz) out = (27.5 to 28.5 MHz) x = 2 if band 2 is selected in = (950 to 2050 MHz) out = (28.0 to 29.0 MHz)
  • Page 9 Table 2.1 Model 4115-300 M&C Queries (Continued from page 7...) Table 2.1: Model 4115-300 M&C Queries - Continued... Queries Syntax Description Returns {aaSOxxxxx} where: Int. 10 MHz reference offset {aaSO} xxxxx = 5 characters Range: +2000 to +8000 Unit Status...
  • Page 10: Ethernet Interface Installation

    The 4115-300 is set at the factory with a static address of 192.168.123.2. The device server in the 4115-300 has a built in HTTP based configuration manager that is used to configure network settings. To access the configuration manager open a web browser and enter the IP address of the 4115-300 in the browser's address field.
  • Page 11: Web Page M&C

    Enter the following address in a web browser to access the M & C web page: http://<ip address of 41xx>/serial/0/setup .htm where <ip address> is the IP address of the unit. Figure 2-C shows the web page from a model 4115-300 frequency converter. 4115-300 Manual, Rev. H...
  • Page 12: Snmp Configuration

    “Connect To” dialog box. Select TCP/IP (Winsock) from the “Connect” using drop down menu. Enter the IP address of the 4115-300 in the “Host address:” field and 9999 in the “Port number” field. Figure 2-E shows an example of the Hyper Terminal settings required to access the SNMP configuration menu.
  • Page 13 SNMP traps are not implemented. The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server 4115-300 Manual, Rev. H Page 13 11/16/15...
  • Page 14 Figure 2-F: Device Server Configuration Menu 4115-300 Manual, Rev. H Page 14 11/16/15...
  • Page 15 -15 to 0 dBm SMA (female) 50Ω SMA (female) 50Ω RF Output. Insert External 10MHz) input level ±0.5 dB. Reference here (+2 dBn ±8 dBm). 1/4 - 20 Tapped Thru, 4 Places 15.5 12.00 15.875 7.50 4115-300 Manual, Rev. H Page 15 11/16/15...
  • Page 16: Physical Interface

    RS422/RS485 Data In+, RS232 Data In NOTE: Planning Ethernet Access It is recommended that IP knowledgeable customer personnel be consulted as a resource in the installation and use of the Ethernet access features of the Cross Technologies product. 4115-300 Manual, Rev. H Page 16...
  • Page 17: Installation/Operation

    NOTE: If a fuse continues to open, the power supply is most likely defective. 2.8 Connection to AC Power The 4115-300 is furnished with a pre-assembled AC power input cable as described below. * 4115 * 4115-31 AC Power Input Connections...
  • Page 18 ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 4115-300 Manual, Rev. H Page 18 11/16/15...

Table of Contents