Summary of Contents for Cross Technologies 3115-21-109
Page 1
POWER Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
1.0 General 1.1 Equipment Description The 3115-21-109# Block Upconverter converts 0.95-1.85 to 10.90-11.80 GHz or 0.95-2.05 to 11.70-12.80 GHz. The gain range is 0 to +20 dB, adjustable in 0.5±0.5 dB steps. Front panel LEDs indicate Remote operation, PLL Alarm and DC Power. Band select, gain and internal/external/Auto reference frequency selection are controlled by front panel switches or remotely via RS 232C or RS485/422 (Ethernet Optional) and are viewable on the LCD Display.
1.2 Technical Characteristics TABLE 1.0 3115-21-109# Block Upconverter Specifications* Input Characteristics (RF) Impedance / Return Loss 50Ω / 14 dB Frequency Band 1; 2 0.95 to 1.85; 0.95 to 2.05 GHz; Noise Figure, Maximum 20 dB Maximum Gain Input Level Range...
Page 5
50Ω SMA (RF), 75Ω BNC (L-Band) SF - 50Ω SMA (RF), 75Ω F-type (L-BAND) SN - 50Ω SMA (RF), 50Ω N-Type (L-Band) SS - 50Ω SMA (RF), 50Ω SMA (L-Band) Available Connector Options, See Table 2.2, PG 10 3115-21-109# Manual, Rev. 0 Page 5 01/30/19...
A) Remote Serial Interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option Q) M&C Cable Diagram - Cross Technologies Frequency Converters and Frequency Sources Female DB-9...
Page 7
B) Status Requests - Table 1.1 lists the status requests for the 3115-21-109# and briefly describes them. * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. TABLE 1.1 3115-21-109# Sta a tus TABLE 1.1 3115-21-109# Status Requests...
Page 8
C) Commands Table 1.2 lists the commands for the 3115-21-109# and briefly describes them. After a command is sent the 3115 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {CND...}, where:...
The 3115 is powered by a 100-240 ± 10% VAC power supply, and housed in a 1 3/4” X 19” X 14” rack mount chassis. The 3115-21-109# can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 3115-21-109# is assembled.
FIGURE 2.2 3115-21-109# Front Panel Controls and Indicators 2.4 Installation / Operation 2.4.1 Installing and Operating the 3115-21-109# 1. Connect a -40 dBm to -20 dBm signal to RF IN, J1 (Figure 2.1). 2. Connect the RF OUT, J101, to the external equipment.
If programming is initiated and no operator action takes place for approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 3115-21-109# Manual, Rev. 0 Page 12 01/30/19...
Page 13
During gain changes, the vertical movement will raise or lower the number in the direction of the arrows. b. For other functions such Remote on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 3115-21-109# Manual, Rev. 0 Page 13 01/30/19...
Page 14
OR you can scroll to “R”, push the Menu/Execute switch to get to: SAVE SETTINGS? Selecting Y will save the new settings. Selecting N will revert to the previous settings. Figure 2.4 (page 15) gives the menu items and how to make changes. 3115-21-109# Manual, Rev. 0 Page 14 01/30/19...
Page 15
Internal 10 MHz Reference. REF = AUTO -I appears on the front panel display where -I indicates that the unit is using the Internal 10 MHz Reference. The Internal 10 MHz Reference is present on the reference output connector, J8. 3115-21-109# Manual, Rev. 0 Page 15 01/30/19...
Page 16
PUSH BUTTON SCROLL <> RS485 ADDRESS = 0 Menu 8 Set RS485 Address SCROLL PUSH BUTTON Save? When go to end SCROLL <> SAVE SETTINGS? SCROLL PUSH BUTTON FIGURE 2.4 Menu Display and Sequences 3115-21-109# Manual, Rev. 0 Page 16 01/30/19...
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 3115-21-109# Manual, Rev. 0 Page 17 01/30/19...
Need help?
Do you have a question about the 3115-21-109 and is the answer not in the manual?