Dometic Coolmatic RPD50 Installation And Operating Manual

Refrigeration, compressor refrigerator

Advertisement

REFRIGERATION
COOLMATIC
RPD50
Compressor refrigerator
EN
Installation and Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for Dometic Coolmatic RPD50

  • Page 1 REFRIGERATION COOLMATIC RPD50 Compressor refrigerator Installation and Operating Manual...
  • Page 2: Table Of Contents

    RPD50 Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it. The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation.
  • Page 3: Explanation Of Symbols

    RPD50 Explanation of symbols Explanation of symbols DANGER! Safety instruction: Failure to observe this instruction will cause fatal or serious injury. WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.
  • Page 4 Safety instructions RPD50 General safety DANGER! • On boats: If the device is powered by the mains, ensure that the power supply has a residual current circuit breaker. WARNING! • Have a qualified technician perform the installation in wet rooms. •...
  • Page 5 RPD50 Safety instructions • If the refrigerator is connected to the DC socket: Disconnect the refrigerator or switch it off when you turn off the engine. Otherwise you may discharge the battery. • The refrigerator is not suitable for storing substances which are caustic or contain solvents.
  • Page 6: Scope Of Delivery

    Scope of delivery RPD50 • Ensure that the ventilation vents are not covered. • Do not fill the inner container with ice or fluid. • Never immerse the appliance in water. • Protect the appliance and the cable against heat and moisture. •...
  • Page 7: Technical Description

    Technical description Technical description The CoolMatic RPD50 refrigerator is suitable for use with a 12 Vg or 24 Vg voltage and can therefore also be used for camping or on boats. It can also be connected to a 120 Vw mains supply via the EPS100W and MPS35 rectifiers.
  • Page 8: Setting Up And Connecting The Refrigerator

    Setting up and connecting the refrigerator RPD50 Setting up and connecting the refrigerator Setting up the refrigerator min. 50 mm In continuous operation, the air humidity may not exceed 90 %. Set up the refrigerator in a dry, sheltered place. Avoid placing it near heat sources such as radiators, gas ovens or hot water pipes.
  • Page 9 RPD50 Setting up and connecting the refrigerator No. in fig. 2, Explanation page 8 Hot waste air Cold intake air Condenser With cover panel 50 mm above Removing the transport protection The refrigerator has a locking mechanism to protect it during transport. The follow- ing settings are possible: •...
  • Page 10 Setting up and connecting the refrigerator RPD50 Changing the door hinge You can also change the hinge of the door, so that it opens to the left rather than the right. To change the door hinge, proceed as follows (fig. 4): ➤...
  • Page 11 RPD50 Setting up and connecting the refrigerator Changing the decorative plate You can change the decorative plate on your refrigerator to improve the appear- ance. This is how to change the decorative plate: ➤ Remove the screws 1 and 3 (fig. 5 1 and 3). ➤...
  • Page 12 Setting up and connecting the refrigerator RPD50 Connecting the refrigerator br bl rt sw rt sw For the electrical connection, please refer to the wiring diagram (fig. 6):...
  • Page 13 RPD50 Setting up and connecting the refrigerator No. in fig. 6, Meaning page 12 Electronic terminal rail Compressor DC fan (if present) Interior lighting Voltage controller for interior lighting (only on devices with interior lighting) Mechanical thermostat Cable colours: No. in fig.
  • Page 14 Setting up and connecting the refrigerator RPD50 Connecting to a battery Ø/mm² 12 V 24 V The refrigerator can be operated with a 12 Vg to 24 Vg voltage supply. NOTICE! To avoid voltage loss and therefore a drop in performance, the cable should be kept as short as possible and should not be interrupted if this is possible.
  • Page 15 RPD50 Setting up and connecting the refrigerator NOTICE! Disconnect the cooling device and other power consuming devices from the battery before connecting the battery to a quick charging device. Overvoltage can damage the electronics of the device. For safety reasons the refrigerator is equipped with an electronic system to prevent the polarity being reversed.
  • Page 16: Using The Refrigerator

    Using the refrigerator RPD50 Using the refrigerator NOTE Before starting your new refrigerator for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to the chapter “Cleaning and maintenance” on page 19). Energy saving tips •...
  • Page 17 RPD50 Using the refrigerator Setting the temperature You can set the temperature to any level using the knob. The built-in thermostat regulates the temperature as follows: • min. (left limit) = warmest setting • max. (right limit) = coldest setting NOTE The cooling capacity can be influenced by •...
  • Page 18 Using the refrigerator RPD50 Defrosting the refrigerator Humidity can form frost in the interior of the refrigerator or on the vaporiser. This reduces the cooling capacity. Defrost the device in good time to avoid this. NOTICE! Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.
  • Page 19: Cleaning And Maintenance

    RPD50 Cleaning and maintenance Cleaning and maintenance WARNING! Always disconnect the refrigerator from the mains before you clean and service it. NOTICE! • Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the refrigerator. •...
  • Page 20: Guarantee

    Guarantee RPD50 Guarantee The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer. For repair and guarantee processing, please include the following documents when you send in the device: •...
  • Page 21: Troubleshooting

    RPD50 Troubleshooting Troubleshooting Compressor does not run Fault Possible cause Remedy = 0 V The connection between the battery Establish a connection Term and the electronics is interrupted Main switch defective (if installed) Replace the main switch Additional supply line fuse has blown Replacing the fuse (if installed) ≤...
  • Page 22 Troubleshooting RPD50 Interior temperature too low in control setting 1 Fault Possible cause Remedy Compressor runs con- Thermostat sensor has no contact to Secure the sensor stantly the vaporiser Thermostat defective Change the thermostat Compressor runs for a Large quantities have been frozen in –...
  • Page 23: Technical Data

    RPD50 Technical data Technical data RPD50 9105204447 Ref. no: Connection voltage: 12 Vg 24 Vg Connection voltage depending on version 120 Vw (see the type plate on the refrigerator) additionally: Refrigerator compartment temperature: +10 °C to +2 °C Freezer compartment temperature: 0 °C to max.
  • Page 24 Dometic (Pty) Ltd. Dometic Austria GmbH MEXICO Regional Office Neudorferstraße 108 Dometic Mx, S. de R. L. de C. V. South Africa & Sub-Saharan Africa A-2353 Guntramsdorf Circuito Médicos No. 6 Local 1 2 Avalon Road  +43 2236 908070 Colonia Ciudad Satélite...