A
NOTICE!
Disconnect the cooling device and other power consuming devices
from the battery before connecting the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
For safety reasons the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting. To protect the battery, the
refrigerator switches off automatically if the voltage is insufficient (see table below).
Switch-off voltage
Switch-on voltage
Connecting to 120 V mains supply
D
DANGER!
Never handle plugs and switches with wet hands or if you are standing
in a puddle.
A
NOTICE!
• If you are operating your refrigerator on board a boat with a mains
connection of 120 V from the land, you must install a ground
protection circuit breaker between the 120 V mains supply and the
refrigerator.
Seek advice from a trained technician.
• When a refrigerator is connected with a factory-supplied
120 V connection line, the AC mains supply used must be fitted with
a 4-amp fuse in phase (L).
➤ To operate the refrigerator on the 120 V mains, use the EPS100W or MPS35
rectifier.
EN
Setting up and connecting the refrigerator
12 V
10,4 V
11,7 V
24 V
22,8 V
24,2 V